Aim: A novel multi-electrode pulmonary vein ablation catheter (PVAC) combining circular mapping and duty-cycled multi-electrode radiofrequency (RF) energy delivery has been developed to map and isolate the pulmonary veins (PVs). The aim of this study was to assess the efficacy of multi-electrode RF ablation using the PVAC device.
Methods And Results: A total of 102 consecutive patients, age 57.9 +/- 9.6 years, with paroxysmal or persistent drug refractory atrial fibrillation (AF) were referred for ablation. All patients had documented AF episodes with an AF duration of 9.3 +/- 7.5 years (range 1.5-25). The mean total procedure time was 139.30 +/- 37.72 (median 135, range 115-172). The mean fluoroscopy time required for PVAC ablation was 17 +/- 12 min (median 16, range 12-33) and the total fluoroscopy time was 32.1 +/- 11.3 min (median 29, range 25-39). The mean multi-electrode RF ablation time required to achieve complete PV isolation was 31 +/- 6.7 min (range 16-51). In eight patients with persistent AF, additional ablations were performed to defragment septal and posterior part of the left atrium. In five patients additional RF ablations using conventional catheters were necessary. After multi-electrode duty-cycled RF ablation, 62 of 102 (60.8%) patients were in sustained sinus rhythm without anti-arrhythmic drugs. The mean follow-up duration was 12.2 +/- 3.9 months (range 6-15).
Conclusion: This novel multi-electrode ablation technique can be used for PV isolation and left atrium ablation with a relatively low medium-term success rate after the first ablation of approximately 61%. Larger studies with longer follow-up are required to evaluate the efficacy and whether multi-electrode RF ablation is associated with a different complication rate compared with standard PV isolation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/europace/euq023 | DOI Listing |
Introduction: Pulsed field ablation (PFA) is a form of nonthermal energy that has been recently introduced for pulmonary vein isolation (PVI). A multi-electrode pentaspline catheter for delivery of PFA guided by fluoroscopy has become widely available for clinical use.
Methods And Results: In this study, we aimed to assess whether the addition of electroanatomical mapping (EAM) for confirmation of PVI in the acute phase can increase the efficacy of the procedure in terms of arrhythmia recurrences.
J Interv Card Electrophysiol
November 2024
Division of Cardiovascular Medicine, University of Utah, 30 N 1900 E Rm 4A100, Salt Lake City, UT, 84132-2101, USA.
Background: Radiofrequency balloon (RFB) ablation (HELIOSTAR™, Biosense Webster) has been developed to improve pulmonary vein ablation efficiency over traditional point-by-point RF ablation approaches. We aimed to find effective parameters for RFB ablation that result in chronic scar verified by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR).
Methods: A chronic canine model (n = 8) was used to ablate in the superior vena cava (SVC), the right superior and the left inferior pulmonary vein (RSPV and LIPV), and the left atrial appendage (LAA) with a circumferential ablation approach (RF energy was delivered to all electrodes simultaneously) for 20 s or 60 s.
Pacing Clin Electrophysiol
December 2024
Division of Cardiology, Showa University Northern Yokohama Hospital, Kanagawa, Japan.
Background: In addition to the pulmonary vein, the superior vena cava (SVC) is an important focus of atrial fibrillation (AF). However, SVC isolation may cause serious complications, and appropriate settings and techniques for SVC isolation are lacking.
Methods: This study enrolled 86 consecutive patients with AF who underwent SVC isolation.
Circulation
November 2024
Fuwai Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, China (X.J., H.D., R.G.).
Ann Palliat Med
July 2024
Department of Anesthesiology, Mayo Clinic, Phoenix, AZ, USA.