Owners of imaging modalities using ionising radiation should have a documented quality assurance (QA) program, as well as methods to justify new radiological procedures to ensure safe operation and adequate clinical image quality. This includes having a system for correcting divergences, written imaging protocols, assessment of patient and staff absorbed doses and a documented education and training program. In this work, how some aspects on QA have been implemented in the County of Ostergötland in Sweden, and efforts to standardise and automate the process as an integrated part of the radiology and nuclear medicine QA programs were reviewed. Some key performance parameters have been identified by a Swedish task group of medical physicists to give guidance on selecting relevant QA methods. These include low-contrast resolution, image homogeneity, automatic exposure control, calibration of air kerma-area product metres and patient-dose data registration in the radiological information system, as well as the quality of reading stations and of the transfer of images to the picture archive and communication system. IT-driven methods to automatically assess patient doses and other data on all examinations are being developed and evaluated as well as routines to assess clinical image quality by use of European quality criteria. By assessing both patient absorbed doses and clinical image quality on a routine basis, the medical physicists in our region aim to be able to spend more time on imaging optimisation and less time on periodic testing of the technical performance of the equipment, particularly on aspects that show very few divergences. The role of the Medical Physics Expert is rapidly developing towards a person doing advanced data-analysis and giving scientific support rather than one performing mainly routine periodic measurements. It is concluded that both the European Council directive and the rapid development towards more complex diagnostic imaging systems and procedures support this changing role of the medical physics professional.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/ncq065 | DOI Listing |
Curr Cardiol Rep
January 2025
Hasselt University, Faculty of Medicine and Life Sciences / Limburg Clinical Research Centre, Agoralaan, Diepenbeek, Belgium.
Purpose Of Review: This review aims to explore the complex interplay between atrial functional mitral regurgitation (AFMR), atrial fibrillation (AF), and heart failure with preserved ejection fraction (HFpEF). The goal is to define these conditions, examine their underlying mechanisms, and discuss treatment perspectives, particularly addressing diagnostic challenges.
Recent Findings: Recent research highlights the rising prevalence of AFMR, now accounting for nearly one-third of significant mitral regurgitation cases.
Curr Obes Rep
January 2025
Metabolism and Body Composition, Pennington Biomedical Research Center, Baton Rouge, LA, 70808, USA.
Background: Recent technological advances have introduced novel methods for measuring body composition, each with unique benefits and limitations. The choice of method often depends on the trade-offs between accuracy, cost, participant burden, and the ability to measure specific body composition compartments.
Objective: To review the considerations of cost, accuracy, portability, and participant burden in reference and emerging body composition assessment methods, and to evaluate their clinical applicability.
Eur Arch Otorhinolaryngol
January 2025
Department of Otolaryngology and Head and Neck Surgery, IRCSS AOU San Martino, University of Genoa, Largo Rosanna Benzi 10, 16132, Genoa, Italy.
Purpose: Immunoglobulin G4-related disease (IgG4-RD) is a complex systemic fibroinflammatory condition with different clinical manifestations affecting multiple organ systems. Despite its rarity, the disease presents diagnostic and therapeutic challenges due to its mimicry of malignancies and other immune-mediated disorders. The 2019 American College of Rheumatology/European League Against Rheumatism Classification Criteria for IgG4-Related Disease is the current state of art to confirm the diagnosis of IgG4-RD even in the absence of histological analysis.
View Article and Find Full Text PDFInt Ophthalmol
January 2025
Department of Ophthalmology, Staedtisches Klinikum Dessau, Brandenburg Medical School Theodor Fontane, Dessau, Germany.
Purpose: Uveal melanoma (UM) is the most common primary ocular malignancy. The size and location of the tumor are decisive for brachytherapy with the β-emitting ruthenium-106 (Ru-106) plaque. The treatment of juxtapapillary and juxtafoveolar UM may be challenging because of the proximity or involvement of the macula and optic nerve and high recurrence rates.
View Article and Find Full Text PDFEur Radiol
January 2025
Department of Information Technology, Uppsala University, 75237, Uppsala, Sweden.
Objectives: The aim is to assess the feasibility and accuracy of a novel quantitative ultrasound (US) method based on global speed-of-sound (g-SoS) measurement using conventional US machines, for breast density assessment in comparison to mammographic ACR (m-ACR) categories.
Materials And Methods: In a prospective study, g-SoS was assessed in the upper-outer breast quadrant of 100 women, with 92 of them also having m-ACR assessed by two radiologists across the entire breast. For g-SoS, ultrasonic waves were transmitted from varying transducer locations and the image misalignments between these were then related analytically to breast SoS.