The LMA Supreme has been suggested for use in emergency situations by medical personnel with no experience in endotracheal intubation. We evaluated the LMA Supreme when inserted by non-anaesthetists, firstly in a manikin and then in patients. Fifty airway novices inserted a LMA Supreme in a manikin without any complications so we proceeded to the patient phase. Fifty airway novices inserted the LMA Supreme in anaesthetised patients undergoing elective surgery. First time insertion success rate was 86% and overall insertion success rate was 100%. Mechanical ventilation was successful in all cases. Median (IQR [range]) time to establish an airway was 34 s (26-40 [18-145] s). Median (IQR [range]) pharyngeal seal pressure was 23 cmH(2)O (19-28 [13-40] cmH(2)O). There were no important complications. Results are consistent with previous studies of use of the LMA Supreme by airway experts. We conclude that the LMA supreme is suitable for use by airway novices. Further research is needed before it may be recommended for cardiopulmonary resuscitation and emergency airway use.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1365-2044.2010.06262.x | DOI Listing |
J Anaesthesiol Clin Pharmacol
March 2024
Department of Anaesthesia, AIIMS, Bathinda, Punjab, India.
Cureus
August 2024
Department of Anesthesiology, Saitama Medical University International Medical Center, Saitama, JPN.
Background: Second-generation supraglottic airway devices (SGAs) are pivotal in airway management, with the ability to accommodate gastric tube (GT) insertion. However, research on GT insertion with SGAs under controlled conditions is limited. This study aimed to evaluate the GT insertion performance of SGAs using a manikin.
View Article and Find Full Text PDFEur J Anaesthesiol
September 2024
From the Department of Anaesthesia, Hillingdon Hospital, London, UK (US), the Department of Anaesthesiology, UZLeuven, Leuven (KJ), the Department of Anaesthesia, Northwick Park Hospital, Harrow, Middlesex, London, UK (NL), the Department of Cardiovascular Sciences, KULeuven (MVdV), and the Department of Anaesthesiology, UZLeuven, Leuven, Belgium (MVdV).
AANA J
June 2024
is a Professor of Anesthesiology at Vanderbilt University Medical Center, Nashville, Tennessee. Email: antonio.
Supraglottic airway (SGA) is an alternative to endotracheal intubation, however endotracheal intubation is often essential. One method to convert from an SGA to an endotracheal tube (ETT) is utilizing the SGA as a conduit for fiberoptic-guided advancement of an Aintree catheter (airway exchange catheter), and exchange of the SGA for an ETT. In this prospective randomized study, we compared two SGA devices in facilitating this exchange.
View Article and Find Full Text PDFSci Rep
January 2024
Department of Anesthesiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University (Shandong Provincial Hospital), Jinan, 250014, China.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!