The Acutrak plus compression screw (APCS) (Acumed Inc., Beaverton, OR, USA) is an intramedullary implant which can achieve stable fixation with minimum soft tissue dissection. The characteristics of the APCS include fully-threaded length, headless, cannulated, and variable thread pitch. Twenty-three patients with AO type-B2 ankle fractures treated with lateral fixation by an APCS were retrospectively reviewed. Evaluation of postoperative roentgenograms for adequacy of reduction revealed a good reduction in 22 of 23 (95.7%) patients. The average wound incision was 4.1 cm. The operative time was 25.3 minutes. All the ankle fractures showed radiographic evidence of healing within four months. At the final follow-up, the ankle scores of the patients were evaluated for functional outcomes. Good to excellent results were obtained in 21 (91.3%) patients. No patient complained of symptomatic hardware. In conclusion, lateral fixation of AO type-B2 ankle fractures by APCS offers several advantages including stable fixation, a small surgical wound, less dissection of soft tissue, no palpable hardware, and easy application with a short operating time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2989028PMC
http://dx.doi.org/10.1007/s00264-010-0971-2DOI Listing

Publication Analysis

Top Keywords

ankle fractures
16
lateral fixation
12
type-b2 ankle
12
fixation type-b2
8
acutrak compression
8
compression screw
8
stable fixation
8
soft tissue
8
ankle
5
fractures
4

Similar Publications

This study evaluated patient outcomes of tibiotalocalcaneal (TTC) nailing for ankle fractures in an elderly population. A systematic literature search of PubMed and Google Scholar identified 24 studies involving 657 patients aged over 65. Key outcome measures included union rates, healing time, functional scores, and complications.

View Article and Find Full Text PDF

Chryseobacterium indologenes is a rare human pathogen which is nowadays considered an emerging fearsome organism because of its upcoming antibiotic resistance. We present a quite unique case of a multi drug resistant C. indologenes surgical wound infection in a patient submitted to cannulated screw fixation of a displaced medial malleolus fracture.

View Article and Find Full Text PDF

Background: Ankle fractures continue to increase in incidence and severity in an older, more challenging geriatric population. Medial malleolus fixation with partially threaded cancellous 4.0-mm screws, a common fixation method, has been shown to fail due to pullout strength.

View Article and Find Full Text PDF

Background: The outcome of a secondary subtalar arthrodesis after prior calcaneal fracture has been widely described. However, the surgical treatment has evolved significantly over the past decade, paralleling the shifts observed in primary repair strategies. Therefore, we describe the outcome following a secondary arthrodesis after an intra-articular calcaneal fracture, comparing the in situ (ISA) and bone block distraction arthrodesis (BBDA) techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!