CT colonography after metallic stent placement for acute malignant colonic obstruction.

Radiology

Department of Radiology and Research Institute of Radiology and Department of Surgery, University of Ulsan College of Medicine, Asan Medical Center, 388-1 Poongnap-Dong, Songpa-Gu, Seoul 138-040, Korea.

Published: March 2010

Purpose: To evaluate the feasibility of using computed tomographic (CT) colonography for preoperative examination of the proximal colon after metallic stent placement in patients with acute colon obstruction caused by colorectal cancer.

Materials And Methods: Institutional review board approval was obtained, and patient informed consent was waived. Fifty patients (mean age +/- standard deviation, 58.5 years +/- 11.7), who demonstrated no postprocedural complication after successful placement of self-expandable metallic stents to treat acute colon obstruction caused by cancer, underwent CT colonography 1-43 days (median, 5 days) after stent placement. CT colonography was performed after cathartic preparation by using magnesium citrate (n = 20) or sodium phosphate (n = 3), combined with oral bisacodyl, or by using polyethylene glycol (n = 27). Fecal/fluid tagging was achieved by using 100 mL of meglumine diatrizoate. The colon was distended by means of pressure-monitored CO(2) insufflation. The sensitivity and specificity of CT colonography in evaluating the colon proximal to the stent and CT colonography-related complications were assessed. The 95% confidence intervals (CIs) were calculated for proportional data.

Results: Per-lesion and per-patient sensitivities of CT colonography for lesions 6 mm or larger in diameter in the colon proximal to the stent were 85.7% (12 of 14 lesions; 95% CI: 58.8%, 97.2%) and 90% (nine of 10 patients; 95% CI: 57.4%, 99.9%), respectively. CT colonography depicted all synchronous cancers (two lesions) and advanced adenomas (five lesions). Per-patient specificity for lesions 6 mm and larger in the proximal colon was 85.7% (18 of 21 patients; 95% CI: 64.5%, 95.9%). CT colonography did not generate any false diagnosis of synchronous cancer. False-positive findings at CT colonography did not result in a change in surgical plan for any patients. No CT colonography-associated stent dislodgment/migration or colonic perforation occurred in any patient (95% CI: 0%, 6.2%).

Conclusion: CT colonography is a safe and useful method for preoperative examination of the proximal colon after metallic stent placement in patients with acute colon obstruction caused by cancer. (c) RSNA, 2010.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.09090842DOI Listing

Publication Analysis

Top Keywords

stent placement
16
metallic stent
12
proximal colon
12
acute colon
12
colon obstruction
12
obstruction caused
12
colonography
10
colon
9
preoperative examination
8
examination proximal
8

Similar Publications

This report presents the case of an 8-year-old female with a history of vesicoureteral reflux (VUR) treated with Deflux injections, who developed Ewing sarcoma metastasized to the lungs. Despite the initial resolution of VUR following Deflux procedures, recurrent urinary tract infections prompted further evaluation revealing significant ureteral obstruction. Pre-chemotherapy workup included renal ultrasonography, nuclear medicine renal scan, and cystogram, identifying obstructive uropathy necessitating bilateral ureteral stent placement.

View Article and Find Full Text PDF

Objective: Secondary sclerosing cholangitis (SSC) represents a disease with a poor prognosis increasingly diagnosed in clinical settings. Notably, SSC in critically ill patients (SSC-CIP) is the most frequent cause. Variables associated with worse prognosis remain unclear.

View Article and Find Full Text PDF

Objectives: The primary objective of this case series is to assess the effectiveness of the off-label use of the PROPEL drug-eluting stent, traditionally FDA-approved for sinus surgery, in preventing restenosis following canalplasty in patients with chronic otologic conditions or congenital anomalies. The stent provides both mechanical support to maintain canal patency and localized steroid delivery to reduce inflammation and scarring.

Methods: Four patients with various otologic conditions underwent canalplasty, followed by the placement of drug-eluting stents into the external auditory canal.

View Article and Find Full Text PDF

Background And Aims: Self-expandable metal stents (SEMS) are effective in alleviating malignant colorectal obstruction. However, bowel perforation following SEMS placement remains a significant concern, as it can adversely affect oncological outcomes. This study aimed to evaluate the recurrence and overall survival rates associated with SEMS-related bowel perforations.

View Article and Find Full Text PDF

Introduction: The management of urinary tract stones, particularly kidney allograft stones, presents unique challenges for kidney transplant recipients because of their prevalence and specific clinical considerations. Here, we describe a case in which percutaneous nephrolithotomy was successfully used to fragment a large kidney allograft stone ≥20 mm in size.

Case Presentation: A 57-year-old woman who underwent ureteroureterostomy post simultaneous pancreas-kidney transplantation presented with gross hematuria after 15 years.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!