It is well known that most exclusive-typed immunoassay systems are highly precise but are poor in compatibility of their determinations. Thus, it is difficult to compare the determinations among different systems, posing problems when a patient is transferred to different hospitals or when a laboratory intends to change the system currently used. In the study, we tried to approach how to assure inter-immunoassay compatibility among four different systems through determination of the exchanged calibrators. First, determinations of total protein and albumin, and electrophoretic fractionation demonstrated marked differences among calibrators in their protein constituent. Some calibrators were prepared with human sera, but others were with inorganic or non-human albumin-based solution. Regression analysis of calibrators between the indicated concentrations by manufacturers and those actually determined by the different immunoassay systems revealed that; most slopes were closed to 1.0 for alpha-fetoprotein and prostate-specific antigen, but widely dissociated from 0.28 to 4.71 for CA19-9. In evaluation of clinical serum samples, determinations by one immunoassay system were compared with those converted based on a linear regression equation that was obtained by determination of the exchanged calibrators. However, this procedure could not improve compatibility, and positive effects of conversion varied by immunoassay systems combined, and also by test parameters. With these, we concluded that simple conversion of determinations by using the exchanged calibrators and a statistical linear regression could not provide us with the expected compatibility. Thus, standardization of target molecules or probes, and of calibrator constituent were urgent issue to assure inter-immunoassay compatibility.

Download full-text PDF

Source

Publication Analysis

Top Keywords

immunoassay systems
16
exchanged calibrators
12
approach assure
8
exclusive-typed immunoassay
8
assure inter-immunoassay
8
inter-immunoassay compatibility
8
determination exchanged
8
linear regression
8
compatibility
6
systems
6

Similar Publications

The scientific discipline of endocrinology has been invaluable to our understanding of the estrous cycle. In the second half of the twentieth century the development of immunoassay technologies provided a rapid and sensitive method to quantify circulating concentrations of reproductive hormones and relate them to stage of the estrous cycle and physiological status of the animal. Ovarian ultrasonography provided the ability to track the growth and regression of ovarian structures within the same animal across the estrous cycle in real time and, in combination with hormonal profiling, accurately identify mechanisms regulating the estrous cycle and early pregnancy.

View Article and Find Full Text PDF

A worldwide issue, vitamin D deficiency affects pregnant mothers and babies everywhere, including Indonesia. It involves the adaptive immune system by controlling the production of pro-and anti-inflammatory cytokines and the balance between humoral (Th2) and cell-mediated (Th1) immunity. The aim of this study was to investigate the relationship between vitamin D and the cytokines IL-6 and IL-10 in infants.

View Article and Find Full Text PDF

Background: The rising global burden of breast cancer demands early detection and effective treatment, with a focus on prognostic and predictive markers. The eighth edition of the American Joint Committee on Cancer staging manual introduced a new prognostic staging system to increase the predictive power of the existing anatomical staging system of breast cancer. The current study aimed to establish the correlation between Ki67 expression with molecular subtypes and with the pathological prognostic stage of invasive ductal carcinoma.

View Article and Find Full Text PDF

Psoriasis, a chronic inflammatory skin disease, poses a significant burden on patients' quality of life and healthcare systems. While mild-to-moderate cases are treated topically, usually combined with phototherapy, severe cases require systemic treatment with immunosuppressants, retinoids or biologics. However, all available treatments have drawbacks in terms of efficiency and side effects.

View Article and Find Full Text PDF

Establishing Decisional Cutoff Values of Neurofilament Light Chains in Cerebrospinal Fluid Measured by Fully Automated Chemiluminescent Enzyme Immunoassay.

J Clin Lab Anal

January 2025

Department of Biomedicine, Neurosciences and Advanced Diagnostics, Institute of Clinical Biochemistry, Clinical Molecular Medicine, and Clinical Laboratory Medicine, University of Palermo, Palermo, Italy.

Introduction: Neurofilament light chain (NfL) is one of the most important biomarkers in the field of clinical neurochemistry. Several analytical methods have been developed in the last decade. Recently, Fujirebio introduced a ready-to-use assay kit for measuring NfL levels in the cerebrospinal fluid (CSF) on the fully automated LUMIPULSE G System.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!