An inertial kinetic exercise (IKE, Oconomowoc, WI, USA) machine was created that permits high-velocity workouts suited for injury rehabilitation and speed development in athletes. In addition, its design does not entail the movement of resistance against Earth's gravitational pull. Thus, the design and operation associated with the IKE may be incorporated into novel environments such as space flight. Yet before it can be used for such reasons, IKE data reproducibility must first be ascertained, which serves as the present study's purpose. Methods to assess data reproducibility required subjects (n = 42) to perform 2 IKE elbow flexor trials, each comprising two 60-second sets separated by a 90-second rest. Preceded by a familiarization session on the IKE, subjects were instructed to perform high-speed elbow flexor trial repetitions in good form. Instrumentation entailed an accelerometer and a computer interfaced with software. Maximum and average forces (MF, AF), as well as work (W), were examined for reproducibility with several test-retest measures. Results showed high reproducibility, yet intertrial variability was greater due in part to the length of time between exercise sessions. It was concluded that MF reproducibility was inherently less partly due to the nature of the variable, which entailed a single instantaneous expression over each 60-second set. In contrast, AF and W denoted a cumulative, and thus better overall, representation of total exercise performance. Based on our high reproducibility values, present IKE instrumentation methods appear to be appropriate. Practical applications suggest that coaches and therapists may want to employ an IKE as instrumented in the present study to derive reproducible performance data on people who may use the device under their supervision.

Download full-text PDF

Source
http://dx.doi.org/10.1519/JSC.0b013e3181bf0211DOI Listing

Publication Analysis

Top Keywords

data reproducibility
12
inertial kinetic
8
kinetic exercise
8
elbow flexor
8
high reproducibility
8
ike
7
reproducibility
6
data
4
reproducibility inertial
4
exercise
4

Similar Publications

Introduction: Insight in psychosis, defined as a patient's awareness and judgment of their mental illness, is a complex and evolving concept. Historically, the absence of insight was considered a defining characteristic of psychosis, but recent decades have seen the development of structured tools for its assessment. This systematic review aims to critically appraise the measurement properties of instruments used to assess insight in individuals with schizophrenia spectrum, bridging the gap between theoretical conceptualization and clinical practice.

View Article and Find Full Text PDF

Low agreement and frequent invalid controls in two SARS-CoV-2 T-cell assays in people with compromised immune function.

PLoS One

January 2025

Division of Clinical Epidemiology, Department of Clinical Research, University Hospital Basel, University of Basel, Basel, Switzerland.

T-cell response plays an important role in SARS-CoV-2 immunogenicity. For people living with HIV (PWH) and solid organ transplant (SOT) recipients there is limited evidence on the reliability of commercially available T-cell tests. We assessed 173 blood samples from 81 participants (62 samples from 35 PWH; 111 samples from 46 SOT recipients [lung and kidney]) with two commercial SARS-CoV-2 Interferon-γ (IFN-γ) release assays (IGRA; SARS-CoV-2 IGRA by Euroimmun, and IGRA SARS-CoV-2 by Roche).

View Article and Find Full Text PDF

We examined the reliability and validity of the Brief Physical Activity Assessment Tool (BPAAT) when administered by telephone interview compared to in-person administration. We analyzed data from the Epi-asthma study. Adult participants registered in the participating Portuguese primary health care centres (PCC) completed the BPAAT via telephone.

View Article and Find Full Text PDF

Estimation of Diagnostic Test Accuracy Without Gold Standards.

Stat Med

February 2025

Department of Biostatistics and Beijing International Center for Mathematical Research, Peking University, Beijing, China.

The ideal evaluation of diagnostic test performance requires a reference test that is free of errors. However, for many diseases, obtaining such a "gold standard" reference is either impossible or prohibitively expensive. Estimating test accuracy in the absence of a gold standard is therefore a significant challenge.

View Article and Find Full Text PDF

Humans are curious. Especially children are known for their drive to explore and learn, which is crucial for developing in and navigating through our complex world. Naturally, some children may be more curious than others, leading to differences in how they structure their own learning experiences, subsequently impacting their developmental trajectories.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!