Role of spiral wave pinning in inhomogeneous active media in the termination of atrial fibrillation by electrical cardioversion.

Comput Biol Med

Cardiovascular Research Centre, Department of Cardiology, Royal Adelaide Hospital, University of Adelaide, Adelaide, SA 5000, Australia.

Published: March 2010

Atrial fibrillation is the most common type of arrhythmia to affect humans. One of the treatment modalities for atrial fibrillation is an electrical cardioversion. Electrical cardioversion can result in one of three outcomes: an immediate termination of arrhythmic activity, a delayed termination or unsuccessful termination. The mechanism of delayed termination is unknown. Here we present a model of an atrial fibrillation as a coexistence of several spiral waves pinned to the inhomogeneities in active media. We show that in inhomogeneous system delayed termination can be explained as the unpinning of a spiral wave from inhomogeneities and its termination after collision with the edge of the system.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.compbiomed.2010.02.001DOI Listing

Publication Analysis

Top Keywords

atrial fibrillation
16
electrical cardioversion
12
delayed termination
12
spiral wave
8
active media
8
fibrillation electrical
8
termination
7
role spiral
4
wave pinning
4
pinning inhomogeneous
4

Similar Publications

Purpose: Atrial fibrillation (AF) is the most common chronic cardiac arrhythmia that increases the risk of stroke, primarily due to thrombus formation in the left atrial appendage (LAA). Left atrial appendage occlusion (LAAO) devices offer an alternative to oral anticoagulation for stroke prevention. However, the complex and variable anatomy of the LAA presents significant challenges to device design and deployment.

View Article and Find Full Text PDF

Introduction And Objectives: Pulmonary vein (PV) isolation is one of the cornerstones of rhythm-control therapy for symptomatic atrial fibrillation (AF) patients. Pulsed field ablation (PFA) is a novel ablation modality that involves the application of electrical pulses causing cellular death, and it has preferential tissue specificity. In this study, we aimed to share a one-year single center experience of AF ablation with PFA.

View Article and Find Full Text PDF

Baseline NT-proBNP Non-Response Score and Health Status Measures in Assessing Treatment Responses in Heart Failure with Reduced Ejection Fraction.

Am Heart J

January 2025

Kaufman Center for Heart Failure Treatment and Recovery, Heart Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH. Electronic address:

Background: We aim to validate NT-proBNP nonresponse score (NNRS) previously derived from the PROTECT and BATTLESCARRED studies in comparison with standard health status measures in predicting natriuretic peptide responses in patients with heart failure with reduced ejection fraction.

Methods: Data on the GUIDE-IT trial were used to derive the NNRS based on 4 predictors including baseline NT-proBNP, heart rate, NYHA functional class, and history of atrial fibrillation. The discriminative capacity of the NNRS and health status measures for having NT-proBNP >1,000 pg/mL at 12 months was assessed and compared with baseline or follow-up health status measures including Kansas City Cardiomyopathy Questionnaire Overall Summary Score (KCCQ-OSS), Duke Activity Status Index (DASI), and 6-minute walk distance.

View Article and Find Full Text PDF

Contemporary Insights into LMNA Cardiomyopathy.

Curr Cardiol Rep

January 2025

Cardiovascular Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.

Purpose Of Review: This review aims to explore how a diagnosis of LMNA-related cardiomyopathy (LMNA-CM) informs clinical management, focusing on the prevention and management of its complications, through practical clinical strategies.

Recent Findings: Longitudinal studies have enhanced our understanding of the natural history of LMNA-CM including its arrhythmic and non-arrhythmic complications. A LMNA specific ventricular arrhythmia risk prediction strategy has been integrated into clinical practice guidelines.

View Article and Find Full Text PDF

Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.

Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!