A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Stability-indicating simultaneous determination of paracetamol and three of its related substances using a direct GC/MS method. | LitMetric

Stability-indicating simultaneous determination of paracetamol and three of its related substances using a direct GC/MS method.

J AOAC Int

Alexandria University, Faculty of Pharmacy, Department of Pharmaceutical Analytical Chemistry, Alexandria 21521, Egypt.

Published: March 2010

A simple, direct, and selective stability-indicating GC/MS procedure was developed for the simultaneous determination of paracetamol (PR) and three of its related substances: 4-aminophenol (4-AP), acetanilide (AD), and 4'-chloroacetanilide (4-CA). The method involved resolution of the underivatized compounds using a 100% dimethylpolysiloxane (Rtx-1) column, and MS detection was carried out in the electron-impact mode. The four compounds were completely resolved in less than 11 min. The fragmentation pathways for the four compounds were described, and the structures of the major fragment ions peaks were proposed. Quantification of the analytes was based on measuring their peak areas. The reliability and analytical performance of the proposed method including linearity, range, precision, accuracy, and detection and quantification limits were statistically validated. Calibration curves were linear over the ranges 75-500, 25-350, 25-350, and 25-350 microg/mL for PR, 4-AP, AD, and 4-CA, respectively. The proposed method was successfully applied for the determination of PR and its related substances in laboratory-prepared mixtures of different proportions. Also, it was applied for the assay of PR in several commercially available pharmaceutical formulations with recoveries of 98.95-100.76%.

Download full-text PDF

Source

Publication Analysis

Top Keywords

simultaneous determination
8
determination paracetamol
8
paracetamol three
8
three substances
8
proposed method
8
25-350 25-350
8
stability-indicating simultaneous
4
substances direct
4
direct gc/ms
4
method
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!