This study assesses the accuracy of the Omron HJ-720ITC pedometer at low walking intensities in patients with chronic heart failure. Step accuracy was assessed by visual observation on the treadmill and during free walking at 40, 50, 60, 70, 80 m/min, as well as during self paced walking using the 6 min walk test. A total of ninety-seven patients with heart failure (mean age: 61+/-13, NYHA I, N=30; NYHA II, N=32; NYHA III, N=35) participated in the study. At predefined walking speeds, a statistically significant % error in pedometer accuracy was evident at 60 m/min (p=0.039), and% error increased markedly below this threshold. Highest% error in pedometer accuracy was seen at 40 m/min (mean bias (% error): 28.3+/-9.0%; 95% CI: 21.8-34.7; p<0.001). During self paced walking (6MWT) the absolute% error in pedometer readings was largest in patients with strongest functional limitations and 6 MWT distances <400 m (mean bias (% error): 10.7+/-13.6%; CI 5.6-15.4, p<0.001). The Omron HJ-720ITC pedometer is accurate for monitoring activity in individuals with normal walking behaviour, but seems unsuitable for chronically ill patients characterised by slow walking gaits.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1055/s-0029-1243641 | DOI Listing |
Sci Rep
November 2024
Department of Physical Education, Xiamen University of Technology, Xiamen, 361000, China.
This study aimed to investigate the accuracy and reliability of accelerometer-based pedometers placed on the wrist, waist, and shoe's midsole during walking, running, and stair climbing. Twenty healthy adults were recruited. Steps were recorded by the pedometers and visually assessed from simultaneously recorded video to evaluate the accuracy of each pedometer in different locations of attachment.
View Article and Find Full Text PDFJ Sports Med Phys Fitness
January 2025
German Air Force Center of Aerospace Medicine, Cologne, Germany -
Background: Activity trackers are becoming increasingly popular in everyday life, sport and research. Accurate measurement of step counts is essential for understanding an individual's daily activity levels and promoting healthier lifestyles. As the sensor technology has become very sophisticated, such a device can be worn on the body for several hours or days without restricting the subject's daily activities.
View Article and Find Full Text PDFFront Psychiatry
April 2023
Institute for Healthcare Artificial Intelligence Application, Guangdong Second Provincial General Hospital, Guangzhou, China.
Br J Nutr
October 2023
National Food Institute, Technical University of Denmark, Kongens, Lyngby2800, Denmark.
The European Food Safety Authority has suggested that EU countries implement the 2 × 24 h diet recall (2 × 24 h DR) method and physical activity (PA) measurements for national dietary surveys. Since 2000, Denmark has used 7 d food diaries (7 d FD) with PA questionnaires and measurements. The accuracy of the reported energy intakes (EI) from the two diet methods, pedometer-determined step counts and self-reported time spent in moderate-to-vigorous PA (MVPA) were compared with total energy expenditure measured by the doubly labelled water (TEEDLW) technique and with PA energy expenditure (PAEE), respectively.
View Article and Find Full Text PDFAppl Hum Factors Ergon Conf
January 2023
California State University Long Beach, Long Beach, CA 90815, USA.
The use of mobile health apps has been on the rise, as they allow people to get their health information more conveniently. Many people are using their mobile health apps to track their health status (KC et al., 2021), but there are known issues with people being unable to use their health apps effectively due to poor design.