Objectives: Despite its importance, implant removal torque can be assessed at present only after implantation. This paper presents a new technique to help clinicians preoperatively evaluate implant stability.
Study Design: Planning software has been combined with an in-house finite element solver. Once the clinician has chosen the implant position on the planner, a finite element analysis automatically calculates the primary stability. The process was designed to be as simple and fast as possible for clinical use. This paper describes application of the method to the prediction of removal torque. A preliminary validation has been performed in both polyurethane foam and sheep bone.
Results: The predicted torque is quantitatively equivalent to experimental values with correlation coefficients of >0.7 in both materials.
Conclusions: This preliminary study is a first step toward the introduction of finite element models in computer-assisted surgery. The fact that the process is fast and automatic makes it suitable for a clinical use.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.tripleo.2009.11.010 | DOI Listing |
Biomech Model Mechanobiol
January 2025
Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, 84112, USA.
When infants are admitted to the hospital with skull fractures, providers must distinguish between cases of accidental and abusive head trauma. Limited information about the incident is available in such cases, and witness statements are not always reliable. In this study, we introduce a novel, data-driven approach to predict fall parameters that lead to skull fractures in infants in order to aid in determinations of abusive head trauma.
View Article and Find Full Text PDFOrthop Surg
January 2025
Orthopedics Department, Gongli Hospital of Shanghai Pudong New Area, Shanghai, China.
Objective: Soft tissue defects and postoperative wound healing complications related to calcaneus fractures may result in significant morbidity. The aim of this study was to investigate whether percutaneous minimally invasive screw internal fixation (PMISIF) can change this situation in the treatment of calcaneal fractures, and aimed to explore the mechanical effects of different internal fixation methods on Sanders type III calcaneal fractures through finite element analysis.
Methods: This retrospective analysis focused on 83 patients with Sanders II and III calcaneal fractures from March 2017 to March 2022.
BMC Oral Health
January 2025
Department of Endodontics, Faculty of Dentistry, Erciyes University, Kayseri, Turkey.
Background: This study assessed stress distributions in simulated mandibular molars filled with various materials after the removal of fractured instruments from the apical thirds of the root canals.
Methods: Finite element models of the mesial and distal root canals were created, where fractured instruments were assumed to be removed using a staging platform established with a modified Gates-Glidden bur (Woodpecker, Guangxi, P.R.
BMC Oral Health
January 2025
Faculty of Dentistry, Department of Endodontics, Ondokuz Mayis University, Samsun, Kurupelit, 55139, Turkey.
Background: The aim was to evaluate the stresses in teeth, with external root resorption (ERR) restored with different materials using finite element analysis (FEA).
Methods: In this study, a Micro-CT scan was conducted on a prepared maxillary central tooth. DICOM-compatible images obtained from the sections were converted into stereolithography format using Ctan software.
ACS Nano
January 2025
Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW, U.K.
Carbon dioxide capture underpins an important range of technologies that can help to mitigate climate change. Improved carbon capture technologies that are driven by electrochemistry are under active development, and it was recently found that supercapacitor energy storage devices can reversibly capture and release carbon dioxide. So-called supercapacitive swing adsorption (SSA) has several advantages over traditional carbon dioxide capture technologies such as lower energy consumption and the use of nontoxic materials.