Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aims: microRNA (miRNA) is reported to be present in the blood of humans and has been increasingly suggested as a biomarker for diseases. We aim to determine the potential of cardiac-specific miRNAs in circulation to serve as biomarkers for acute myocardial infarction (AMI).
Methods And Results: By verifying their tissue expression patterns with real-time polymerase chain reaction (PCR) analysis, muscle-enriched miRNAs (miR-1, miR-133a, and miR-499) and cardiac-specific miR-208a were selected as candidates for this study. With miRNA microarray and real-time PCR analyses, miR-1, miR-133a, and miR-499 were present with very low abundance, and miR-208a was absent in the plasma from healthy people. In the AMI rats, the plasma levels of these miRNAs were significantly increased. Especially, miR-208a in plasma was undetected at 0 h, but was significantly increased to a detectable level as early as 1 h after coronary artery occlusion. Further evaluation of the miRNA levels in plasma from AMI patients (n = 33) demonstrated that all four miRNA levels were substantially higher than those from healthy people (n = 30, P < 0.01), patients with non-AMI coronary heart disease (n = 16, P < 0.01), or patients with other cardiovascular diseases (n = 17, P < 0.01). Notably, miR-208a remained undetectable in non-AMI patients, but was easily detected in 90.9% AMI patients and in 100% AMI patients within 4 h of the onset of symptoms. By receiver operating characteristic curve analysis, among the four miRNAs investigated, miR-208a revealed the higher sensitivity and specificity for diagnosing AMI.
Conclusion: Elevated cardiac-specific miR-208a in plasma may be a novel biomarker for early detection of myocardial injury in humans.