Crystal structure of a Legionella pneumophila ecto -triphosphate diphosphohydrolase, a structural and functional homolog of the eukaryotic NTPDases.

Structure

The Protein Crystallography Unit, ARC Centre of Excellence in Structural and Functional Microbial Genomics, Department of Biochemistry and Molecular Biology, School of Biomedical Sciences, Monash University, Clayton, Victoria 3800, Australia.

Published: February 2010

Many pathogenic bacteria have sophisticated mechanisms to interfere with the mammalian immune response. These include the disruption of host extracellular ATP levels that, in humans, is tightly regulated by the nucleoside triphosphate diphosphohydrolase family (NTPDases). NTPDases are found almost exclusively in eukaryotes, the notable exception being their presence in some pathogenic prokaryotes. To address the function of bacterial NTPDases, we describe the structures of an NTPDase from the pathogen Legionella pneumophila (Lpg1905/Lp1NTPDase) in its apo state and in complex with the ATP analog AMPPNP and the subtype-specific NTPDase inhibitor ARL 67156. Lp1NTPDase is structurally and catalytically related to eukaryotic NTPDases and the structure provides a basis for NTPDase-specific inhibition. Furthermore, we demonstrate that the activity of Lp1NTPDase correlates directly with intracellular replication of Legionella within macrophages. Collectively, these findings provide insight into the mechanism of this enzyme and highlight its role in host-pathogen interactions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.str.2009.11.014DOI Listing

Publication Analysis

Top Keywords

legionella pneumophila
8
eukaryotic ntpdases
8
ntpdases
5
crystal structure
4
structure legionella
4
pneumophila ecto
4
ecto -triphosphate
4
-triphosphate diphosphohydrolase
4
diphosphohydrolase structural
4
structural functional
4

Similar Publications

Diabetes impairs IFNγ-dependent antibacterial defense in the lungs.

Mucosal Immunol

December 2024

Department of Infectious Diseases, Respiratory Medicine and Critical Care, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Augustenburger Platz 1, 13353 Berlin, Germany; German center for lung research (DZL), Augustenburger Platz 1, 13353 Berlin, Germany. Electronic address:

Diabetes mellitus is associated with an increased risk of pneumonia, often caused by so-called typical and atypical pathogens including Streptoccocus pneumoniae and Legionella pneumophila, respectively. Here, we employed a variety of mouse models to investigate how diabetes influences pulmonary antibacterial immunity. Following intranasal infection with S.

View Article and Find Full Text PDF

Introduction And Objective: Water in installations in hospitals and social welfare homes (SWHs) should meet the requirements of the Directive of the European Parliament and of the Council on the quality of water intended for human consumption and national regulations issued on its basis. At present, 60 species of bacteria of the genus Legionella sp. are known (of which 30 are considered as pathogenic for humans), and more than 80 serologic groups.

View Article and Find Full Text PDF

Antibiotic susceptibility situation of environmental isolates in Southern Germany.

J Water Health

December 2024

Laboklin GmbH & Co KG, Steubenstraße 4, 97688 Bad Kissingen, Germany.

Antimicrobial resistance is an emerging problem in hospitals and long-term healthcare facilities. Early detection of susceptibility pattern changes in pathogenic bacteria can prevent treatment failures. Therefore, this study chose to investigate the antibiotic susceptibility situation of isolates from hospitals and long-term healthcare facilities in Southern Germany.

View Article and Find Full Text PDF

Laying the groundwork for a risk management program for public drinking water systems.

J Water Health

December 2024

Environmental Science, Policy and Research Institute, 144 Narberth Ave, Box 407, Narberth, PA 19072, USA.

is different from traditional drinking water contaminants because it presents a latent public health risk for public and private drinking water systems and for the building water systems they supply. This paper reviews information on the likelihood of occurrence of in public water systems to lay a foundation for public water systems, as a stakeholder in public health risk management, to better manage . Important to this approach is a literature review to identify conditions that could potentially promote being present in drinking water systems at either an elevated abundance or at an increased frequency of occurrence, and/or water quality and supply conditions that would contribute to its amplification.

View Article and Find Full Text PDF

Hot water systems are the most frequent environment associated with the prevalence and growth of opportunistic premise plumbing pathogens (OPPPs). Previous studies identified water heaters as a source of waterborne diseases and concluded that design variables may contribute to their prevalence. A multifaceted approach was used to investigate the vertical stratification of the microbiome and selected OPPPs in an electric water heater tank connected to a home plumbing system simulator.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!