The effects of (-)-epigallocatechin gallate (EGCG) on pacemaker activities of cultured interstitial cells of Cajal (ICC) from murine small intestine were investigated using whole-cell patch-clamp technique at 30 and Ca(2+) image analysis. ICC generated spontaneous pacemaker currents at a holding potential of -70 mV. The treatment of ICC with EGCG resulted in a dose-dependent decrease in the frequency and amplitude of pacemaker currents. SQ-22536, an adenylate cyclase inhibitor, and ODQ, a guanylate cyclase inhibitor, did not inhibit the effects of EGCG. EGCG-induced effects on pacemaker currents were not inhibited by glibenclamide, an ATP-sensitive K(+) channel blocker and TEA, a Ca(2+)-activated K(+) channel blocker. Also, we found that EGCG inhibited the spontaneous [Ca(2+)](i) oscillations in cultured ICC. In conclusion, EGCG inhibited the pacemaker activity of ICC and reduced [Ca(2+)](i) oscillations by cAMP-, cGMP-, ATP-sensitive K+ channel-independent manner.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2817548PMC
http://dx.doi.org/10.4196/kjpp.2008.12.3.111DOI Listing

Publication Analysis

Top Keywords

pacemaker currents
12
--epigallocatechin gallate
8
pacemaker activity
8
interstitial cells
8
cells cajal
8
small intestine
8
cyclase inhibitor
8
channel blocker
8
egcg inhibited
8
[ca2+]i oscillations
8

Similar Publications

New techniques for largescale neural recordings from diverse animals are reshaping comparative systems neuroscience. This growth necessitates fresh conceptual paradigms for comparing neural circuits and activity patterns. Here, we take a systems neuroscience approach to early neural evolution, emphasizing the importance of considering nervous systems as multiply modulated, continuous dynamical systems.

View Article and Find Full Text PDF

Interstitial cells of Cajal in the plane of the myenteric plexus (ICC-MY) serve as electrical pacemakers in the stomach and small intestine. A similar population of cells is found in the colon, but these cells do not appear to generate regular slow wave potentials, as characteristic in more proximal gut regions. Ca handling mechanisms in ICC-MY of the mouse proximal colon were studied using confocal imaging of muscles from animals expressing GCaMP6f exclusively in ICC.

View Article and Find Full Text PDF

When should the tricuspid valve be repaired during mitral valve repair?

Curr Opin Cardiol

December 2024

Division of Cardiac Surgery, Department of Surgery, Western University, London, Ontario, Canada.

Purpose Of Review: Management of tricuspid regurgitation and annular dilation during mitral valve repair remains controversial. We review the latest evidence on indications to repair the tricuspid valve during mitral valve repair and discuss surgical strategies and complications.

Recent Findings: Concomitant tricuspid valve repair of moderate tricuspid regurgitation is effective in reducing tricuspid regurgitation progression at 2 years, but has not shown benefit to late survival, quality of life, or functional benefit, and is associated with increased permanent pacemaker implantation (PPM) rates, which is associated with reduced late survival.

View Article and Find Full Text PDF

The impact of common and rare genetic variants on bradyarrhythmia development.

Nat Genet

January 2025

Telemachus and Irene Demoulas Family Foundation Center for Cardiac Arrhythmias, Massachusetts General Hospital, Boston, MA, USA.

To broaden our understanding of bradyarrhythmias and conduction disease, we performed common variant genome-wide association analyses in up to 1.3 million individuals and rare variant burden testing in 460,000 individuals for sinus node dysfunction (SND), distal conduction disease (DCD) and pacemaker (PM) implantation. We identified 13, 31 and 21 common variant loci for SND, DCD and PM, respectively.

View Article and Find Full Text PDF

Introduction: Ultrasound (US)-guided axillary vein puncture is a safe and effective approach for cardiac implantable electronic device (CIED) implantation, and it is highly recommended by the current consensus document. However, only reports on small populations are available in the current literature regarding the comparison of this technique with other traditional approaches (subclavian vein blind puncture and cephalic vein surgical cutdown).

Purpose: We aimed to assess the effectiveness and safety of US- guided axillary vein puncture using a microintroducer kit for CIED implantation as compared to the aforementioned traditional approaches.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!