Tuning the Thickness and Orientation of Single Au Pyramids for Improved Refractive Index Sensitivities.

J Phys Chem C Nanomater Interfaces

Department of Chemistry, Northwestern University, 2145 Sheridan Road, Evanston, Illinois 60208-3113.

Published: February 2009

This paper describes three ways to tune the multipolar surface plasmon resonances of Au pyramidal particles: (1) by varying their thickness; (2) by controlling their relative orientation on a surface; and (3) by changing the refractive index of the surrounding media. We found that as the index of the medium was increased that the plasmon resonances red-shifted linearly from visible to near infrared wavelengths. By screening the different geometric parameters, we found that 25-nm thick pyramids in a tip-up orientation produced the largest refractive index sensitivities.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2664166PMC
http://dx.doi.org/10.1021/jp8111155DOI Listing

Publication Analysis

Top Keywords

refractive sensitivities
8
plasmon resonances
8
tuning thickness
4
thickness orientation
4
orientation single
4
single pyramids
4
pyramids improved
4
improved refractive
4
sensitivities paper
4
paper describes
4

Similar Publications

This research proposes an all-metal metamaterial-based absorber with a novel geometry capable of refractive index sensing in the terahertz (THz) range. The structure consists of four concentric diamond-shaped gold resonators on the top of a gold metal plate; the resonators increase in height by 2 µm moving from the outer to the inner resonators, making the design distinctive. This novel configuration has played a very significant role in achieving multiple ultra-narrow resonant absorption peaks that produce very high sensitivity when employed as a refractive index sensor.

View Article and Find Full Text PDF

In this paper, a new sensor structure is designed, which consists of a metal-insulator-metal (MIM) waveguide and a circular protrusion and a rectangular triangular cavity (CPRTC). The characterization of nanoscale sensors is considered using an approximate numerical method (finite element method). The simulation results show that the sharp asymmetric resonance generated by the interaction between the discrete narrow-band mode and the continuous wideband mode is called Fano resonance.

View Article and Find Full Text PDF

Refractive index (RI) and temperature (T) are both critical environmental parameters for environmental monitoring, food production, and medical testing. The paper develops a D-shaped photonic crystal fiber (PCF) sensor to measure RI and T simultaneously. Its cross-sectional structure encompasses a hexagonal-hole lattice, with one hole selectively filled with toluene for temperature sensing.

View Article and Find Full Text PDF

Analysis of Refractive Index Sensing Properties of a Hybrid Hollow Cylindrical Tetramer Array.

Nanomaterials (Basel)

January 2025

Xinjiang Key Laboratory for Luminescence Minerals and Optical Functional Materials, School of Physics and Electronic Engineering, Xinjiang Normal University, Urumqi 830054, China.

In recent years, metal surface plasmon resonance sensors and dielectric guided-mode resonance sensors have attracted the attention of researchers. Metal sensors are sensitive to environmental disturbances but have high optical losses, while dielectric sensors have low losses but limited sensitivity. To overcome these limitations, hybrid resonance sensors that combine the advantages of metal and dielectric were proposed to achieve a high sensitivity and a high factor at the same time.

View Article and Find Full Text PDF

The detection of low-molecular-weight biomarkers is essential for diagnosing and managing various diseases, including neurodegenerative conditions such as Alzheimer's disease. A biomarker's low molecular weight is a challenge for label-free optical modalities, as the phase change they detect is directly proportional to the mass bound on the sensor's surface. To address this challenge, we used a resonant Young's slit interferometer geometry and implemented several innovations, such as phase noise matching and optimisation of the fringe spacing, to maximise the signal-to-noise ratio.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!