Background: The rapidly evolving pandemic of novel 2009 swine-origin influenza A (H1N1) virus (S-OIV) demands that accurate and practical diagnostics be urgently evaluated for their potential clinical utility.
Objective: To determine the diagnostic accuracy of a rapid influenza diagnostic test (RIDT) and direct fluorescent antibody (DFA) assay for S-OIV by using reverse-transcription polymerase chain reaction (RT-PCR) as the reference standard.
Methods: We prospectively recruited children (aged 0-17 years) assessed in the emergency department of a pediatric referral hospital and a community pediatric clinic for influenza-like illness between May 22 and July 25, 2009. RIDT (performed on-site) and DFA were compared with RT-PCR to determine their sensitivity and specificity for S-OIV. We also compared the sensitivity of RIDT for S-OIV to that for seasonal influenza over 2 preceding seasons.
Results: Of 820 children enrolled, 651 were from the emergency department and 169 were from the clinic. RIDT sensitivity was 62% (95% confidence interval [CI]: 52%-70%) for S-OIV, with a specificity of 99% (95% CI: 92%-100%). DFA sensitivity was 83% (95% CI: 75%-89%) and was superior to that of RIDT (P < .001). RIDT sensitivity for S-OIV was comparable to that for seasonal influenza when using DFA supplemented with culture as the reference standard. RIDT sensitivity for influenza viruses was significantly higher in children 5 years of age or younger (P = .003) and in patients presenting < or =2 days after symptom onset (P < .001).
Conclusions: The sensitivity of RIDT for detection of S-OIV is higher than recently reported in mixed adult-pediatric populations but remains suboptimal.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1542/peds.2009-2669 | DOI Listing |
J Med Virol
January 2025
Radiology department, Tianjin Fifth Central Hospital, Tianjin, China.
To evaluate the performance of three rapid influenza diagnostic tests (RIDTs) for detecting influenza A and B viruses compared to RT-PCR. A total of 291 subjects with acute respiratory infections were enrolled. Respiratory specimens were collected and tested for influenza A and B viruses using three RIDTs.
View Article and Find Full Text PDFPLOS Glob Public Health
May 2023
Wisconsin State Laboratory of Hygiene, Madison, Wisconsin, United States of America.
Rapid influenza diagnostic tests (RIDT) demonstrate varying sensitivities, often necessitating reverse transcriptase polymerase chain reaction (RT-PCR) to confirm results. The two methods generally require separate specimens. Using the same anterior nasal swab for both RIDT and molecular confirmation would reduce cost and waste and increase patient comfort.
View Article and Find Full Text PDFInfluenza Other Respir Viruses
January 2023
Department of Family Medicine and Community Health, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Rapid influenza diagnostic tests (RIDTs) have variable sensitivity. In a community-based population of kindergarten through 12th-grade (K-12) students, we assessed factors that may influence RIDT performance using 2368 paired results from Sofia® influenza A + B fluorescent immunoassay and reverse transcription polymerase chain reaction (RT-PCR). RIDT sensitivity and specificity were 76.
View Article and Find Full Text PDFDiagn Microbiol Infect Dis
February 2023
Division of Emergency Medicine, Children's National Health System, Wshington, DC, USA; George Washington University School of Medicine and Health Sciences, Washington, DC, USA.
Introduction: Despite a sensitivity of 50% to 70% the rapid influenza diagnostic test (RIDT) continues to play an important role in clinical decision-making due to its quick turn-around time, high specificity, relative simplicity of use, and low cost.
Methods: A quantitative study using a web-based survey was distributed to 110 members of the Society of Pediatric Urgent Care aimed to assess RIDT use for diagnosis and management of influenza in outpatient pediatric patients.
Results: Responses from 61 providers were received.
J Osteopath Med
January 2023
Omni International, Inc, A PerkinElmer Company, Kennesaw, GA, USA.
Context: Rapid influenza diagnostic tests (RIDTs) are becoming increasingly accurate, available, and reliable as the first line of testing when suspecting influenza infections, although the global burden of influenza infections remains high. Rapid diagnosis of influenza infections has been shown to reduce improper or delayed treatment and to increase access to diagnostic measures in public health, primary care, and hospital-based settings.
Objectives: As the use of RIDTs continues to expand in all healthcare settings, there is a multitude of molecular techniques being employed by these various testing platforms.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!