Poor postural balance is one of the major risk factors for falling in normal pressure hydrocephalus (NPH). Postural instability in the clinic is commonly assessed based upon force platform posturography. In this study we focused on the identification of changes in sway characteristics while standing quiet in patients with NPH before and after shunt implantation. Postural sway area and sway radius were analyzed in a group of 9 patients and 46 controls of both genders. Subject's spontaneous sway was recorded while standing quiet on a force platform for 30-60 s, with eyes open and then closed. Both analyzed sway descriptors identified between-group differences and also an effect of shunt implantation in the NPH group. Sway radius and sway area in patients exhibited very high values compared with those in the control group. Importantly, the effect of eyesight in patients was not observed before shunt implantation and reappeared after the surgical treatment. The study documents that static force platform posturography may be a reliable measure of postural control improvement due to shunt surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3521352PMC
http://dx.doi.org/10.1186/2047-783x-14-s4-53DOI Listing

Publication Analysis

Top Keywords

shunt implantation
16
force platform
12
sway
8
postural sway
8
normal pressure
8
pressure hydrocephalus
8
platform posturography
8
standing quiet
8
sway area
8
sway radius
8

Similar Publications

Optimizing the life of vascular access during follow-up.

J Cardiovasc Surg (Torino)

February 2025

Department of Vascular Surgery, ASST Settelaghi Universitary Teaching Hospital, University of Insubria, Varese, Italy.

Optimizing the longevity of vascular access in hemodialysis patients remains a critical aspect of patient care, given the significant role of arteriovenous fistulas (AVFs) and arteriovenous grafts (AVGs) in enabling effective dialysis. Vascular access complications, such as stenosis, thrombosis, and cannulation-related damage, continue to challenge both the functionality and the sustainability of these access points. Recent advancements underscore the importance of a robust follow-up strategy, integrating clinical evaluations with diagnostic tools like color Doppler ultrasound (CDU) and emerging interventional approaches such as drug-coated balloon (DCB) angioplasty.

View Article and Find Full Text PDF

Background: Superior caval vein obstruction is a rare complication of endocardial pacing lead implantation that can result in a right to left shunt.

Case Summary: A 3-year-old child with type 2 Brugada syndrome presented with mild cyanosis post-endocardial pacing implantation due to evolutionary right superior caval vein obstruction. This obstruction resulted in a right to left shunt across a previously unrecognized patent levo-atrial cardinal vein associated with partial anomalous pulmonary venous drainage.

View Article and Find Full Text PDF

Left atrial shunting devices: why, what, how, and… when?

Heart Fail Rev

January 2025

Department of Cardiology, San Luca Hospital, IRCCS Istituto Auxologico Italiano, Milan, Italy.

Left atrial (LA) hypertension is central in the pathophysiology of heart failure (HF) in general and of HF with preserved ejection fraction (HFpEF) in particular. Despite approved treatments, a number of HF patients continue experiencing disabling symptoms due to LA hypertension, causing pulmonary congestion, pulmonary hypertension, and right heart dysfunction, at rest and/or during exercise. LA decompression therapies, i.

View Article and Find Full Text PDF

Purpose: To assess the safety and efficacy of a modified suprachoroidal silicone tube (SST) shunt in patients with primary open-angle glaucoma (POAG) and pseudo-exfoliative glaucoma (PXG) in this experimental study.

Methods: In this single-center, retrospective longitudinal data analysis 66 eyes of 59 patients having POAG and PXG were included and treated with modified SST shunt in combination with cataract or as a stand-alone procedure. Pre- and postoperative intraocular pressure (IOP), best corrected visual acuity (BCVA), C/D ratio and ocular adverse events (AEs) were assessed in all participants.

View Article and Find Full Text PDF

Communicating hydrocephalus following stereotactic radiosurgery for periventricular meningiomas: illustrative cases.

J Neurosurg Case Lessons

January 2025

Victor Horsley Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, University College London Hospitals, London, United Kingdom.

Background: Stereotactic radiosurgery (SRS) is a well-established option for the management of intracranial tumors, including meningiomas. Although valued for its low invasiveness and precision, it still carries a risk of complications. Communicating hydrocephalus is a serious, albeit rarely reported, complication of SRS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!