Purpose: The use of a 2.0-mm locking plate system was evaluated in mandibular surgery.
Patients And Methods: 53 patients (42 male, 11 female) with a total of 56 mandibular fractures were treated with a 2.0-mm mini-locking-plate system and retrospectively examined. Gender, age, cause of fracture, surgical access, classification of fractures, osteosynthesis, postsurgical findings and complications were evaluated.
Results: Assault in male patients (mean age 31) was the most common aetiological factor. Fractures in women (mean age 43 years) mostly occurred due to falls. Mandibular angle fractures were the most common and this anatomical site also presented the highest complication rate. Only 6% of patients had minor occlusal disturbance postoperatively, and minor complications (infections and dehiscence) occurred in 14% of patients in this study. Major complications only occurred in one patient included in the study (1.9%). Risk factors for the development of complications in this series were a history of alcohol or tobacco use, mandibular angle fractures, associated facial fractures, presurgical occlusal disturbance and concomitant dental infections. Surgical access to the fracture and the interval from injury to surgery was not associated with the development of complications.
Conclusions: The use of a 2.0-mm locking plate system with its advantages of improved handling characteristics, increased stability, shorter surgical time and the preservation of bony perfusion is a viable alternative to conventional miniplates in the management of mandibular fractures.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcms.2010.01.001 | DOI Listing |
Vet Comp Orthop Traumatol
January 2025
School of Engineering, University of Guelph, Guelph, Ontario, Canada.
Objective: To determine the effect of locking head inserts (LHI) on plate strain, stiffness, and deformation when applied to a 3.5-mm broad locking compression plate (LCP) in an open fracture-gap model.
Study Design: Six, 13-hole, 3.
Injury
December 2024
Golden Jubilee Medical Center, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Background: Severe metaphyseal comminution and sizable bone defect of the distal femur are high risks of fixation failure. To date, no exact magnitude of comminution and bone loss is determined as an indication for augmentation of fixation construct. The present study aimed to investigate the influence of metaphyseal gap width, working length, and screw distribution on the stability of the fixation construct.
View Article and Find Full Text PDFAnal Chem
September 2024
State Key Laboratory of Chemical Resource Engineering, College of Chemistry, Beijing University of Chemical Technology, Beijing 10010, P. R. China.
World J Pediatr
October 2024
Sydney Medical School, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia.
Background: Button battery (BB) exposures are common in children and can have devastating consequences. We reviewed current evidence on the complications associated with BB exposure and identified predictors of outcomes using individual patient-level data.
Data Sources: We carried out a systematic review and pooled analysis by searching MEDLINE, Embase, and Scopus up to May 19, 2023.
Background: Displaced diaphyseal fractures can be reduced using the push-pull technique, wherein a plate is affixed to the distal fragment of the fracture, a post screw is placed proximal to the plate, and a lamina spreader creates distraction. This study evaluated the load to failure and mechanism of failure of bicortical and unicortical post screws during reduction.
Materials And Methods: Four matched pairs of cadaver legs were subjected to a 2-cm oblique osteotomy simulating a displaced, oblique diaphyseal fracture.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!