Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: In expert hands, the intrathoracic oesophago-gastric anastamosis usually provides a low rate of strictures and leaks. However, anastomoses can be technically challenging and time consuming when minimally invasive techniques are used. We present our preliminary results of a standardised 25 mm/4.8mm circular-stapled anastomosis using a trans-orally placed anvil.
Materials And Methods: We evaluated a prospective cohort of 37 consecutive patients offered minimally invasive Ivor Lewis oesophagectomy at a tertiary referral centre. The oesophago-gastric anastomosis was created using a 25-mm anvil (Orvil, Autosuture, Norwalk, CT, USA) passed trans-orally, in a tilted position, and connected to a 90-cm long polyvinyl chloride delivery tube through an opening in the oesophageal stump. The anastomosis was completed by joining the anvil to a circular stapler (end-to-end anastomosis stapler (EEA XL) 25 mm with 4.8-mm staples, Autosuture, Norwalk, CT, USA) inserted into the gastric conduit. Primary outcomes were leak and stricture rates.
Results: Thirty-seven patients (mean age 65 years) with distal oesophageal adenocarcinoma (n=29), squamous cell cancer (n=5) or high-grade dysplasia in Barrett's oesophagus (n=3) underwent an Ivor Lewis oesophagectomy between October 2007 and August 2009. The abdominal portion was operated laparoscopically in 30 patients (81.1%). The thoracic portion was done using a muscle-sparing mini-thoracotomy in 23 patients (62.2%) and thoracoscopic techniques in 14 patients (37.8%). There were no intra-operative technical failures of the anastomosis or deaths. Five patients had strictures (13.5%) and all were successfully treated with endoscopic dilations. One patient had an anastomotic leak (2.7%) that was successfully treated by re-operation and endoscopic stenting of the anastomosis.
Discussion: The circular-stapled anastomosis with the trans-oral anvil allows for an efficient, safe and reproducible anastomosis. This straightforward technique is particularly suited to the completely minimally invasive Ivor Lewis oesophagectomy.