A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An aptamer-based assay for thrombin via structure switch based on gold nanoparticles and magnetic nanoparticles. | LitMetric

An aptamer-based assay for thrombin with high specificity and sensitivity was presented. In the protocol, the aptamer for thrombin was immobilized on magnetic nanoparticle, and its complementary oligonucleotide was labeled with gold nanoparticles, then the aptamer was hybridized with the complementary oligonucleotide to form the duplex structure as a probe, this probe could be used for the specific recognition for thrombin. In the presence of thrombin, the aptamer prefer to form the G-quarter structure with thrombin, resulting in the dissociation of the duplex of the probe and the release of the gold labeled oligonucleotide. Upon this, we were able to detect thrombin through the detection of the electrochemical signal of gold nanoparticles. The strategy combines with the high specificity of aptamer and the excellent characteristics of nanoparticles. This assay is simple, rapid, sensitive and highly specific, it does not require labeling of thrombin, and it could be applied to detect thrombin in complex real sample. The method shows great potential in other protein analysis and in disease diagnosis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2009.10.036DOI Listing

Publication Analysis

Top Keywords

gold nanoparticles
12
thrombin
9
aptamer-based assay
8
assay thrombin
8
high specificity
8
complementary oligonucleotide
8
detect thrombin
8
nanoparticles
5
thrombin structure
4
structure switch
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!