A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous determination of angiotensins II and 1-7 by capillary zone electrophoresis in plasma and urine from hypertensive rats. | LitMetric

Simultaneous determination of angiotensins II and 1-7 by capillary zone electrophoresis in plasma and urine from hypertensive rats.

Talanta

Departamento de Farmacología, Instituto Nacional de Cardiología Ignacio Chávez, Juan Badiano No 1, Col Sección XVI, 14080 Tlalpan, México DF, Mexico.

Published: March 2010

We describe the procedure developed for the simultaneous detection and quantification of angiotensin II and angiotensin-(1-7), by capillary zone electrophoresis with UV detection by photodiode-array, at a wavelength of 200 nm, in the plasma and urine from hypertensive rats. Optimal separation was achieved with a 100mM boric acid+3mM tartaric acid+10 fM gold (III) chloride electrolyte solution at pH 9.80. The applied voltage was 30 kV and the capillary temperature was kept constant at 20 degrees C. The method was over the concentration range of 0.01-500 pmol/mL. All determination coefficients were higher or equal to 0.9985. Limits of detection and quantification for angiotensin II were 0.0110 pmol/mL (S/N=3) and 0.0195 pmol/mL (S/N=5), respectively. While for angiotensin-(1-7), the limits were 0.0112 pmol/mL (S/N=3) and 0.0193 pmol/mL (S/N=5), respectively. The present method offers a time-saving way to simultaneous determination of angiotensin II and angiotensin-(1-7), since it can be completed in 10 min, compared to other methodologies reported in the literature for capillary electrophoresis and liquid chromatography, which require more than 1h for analysis of complex matrices, such as plasma and urine. The procedure is illustrated by experiments that quantify simultaneously angiotensin II and angiotensin-(1-7) in plasma and urine from hypertensive and normotensive rats, with and without antihypertensive treatment. The levels of angiotensin II and angiotensin-(1-7) detected in the experimental model, resulted in a recovery of 99.00-106.01% and a reproducibility of less than 10%. The proposed analytical method is a use full tool for the simultaneous detection of angiotensin II and angiotensin-(1-7) implicated in vascular remodeling in pathologies such as hypertension.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2009.10.010DOI Listing

Publication Analysis

Top Keywords

angiotensin angiotensin-1-7
20
plasma urine
16
urine hypertensive
12
simultaneous determination
8
capillary zone
8
zone electrophoresis
8
hypertensive rats
8
simultaneous detection
8
detection quantification
8
quantification angiotensin
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!