A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Transient-evoked and distortion product otoacoustic emissions: A short-term test-retest reliability study. | LitMetric

Knowledge regarding the variability of transient-evoked otoacoustic emissions (TEOAEs) and distortion product otoacoustic emissions (DPOAEs) is essential in clinical settings and improves their utility in monitoring hearing status over time. In the current study, TEOAEs and DPOAEs were measured with commercially available OAE-equipment in 56 normally-hearing ears during three sessions. Reliability was analysed for the retest measurement without probe-refitting, the immediate retest measurement with probe-refitting, and retest measurements after one hour and one week. The highest reliability was obtained in the retest measurement without probe-refitting, and decreased with increasing time-interval between measurements. For TEOAEs, the lowest reliability was seen at half-octave frequency bands 1.0 and 1.4 kHz; whereas for DPOAEs half-octave frequency band 8.0 kHz had also poor reliability. Higher primary tone level combination for DPOAEs yielded to a better reliability of DPOAE amplitudes. External environmental noise seemed to be the dominating noise source in normal-hearing subjects, decreasing the reliability of emission amplitudes especially in the low-frequency region.

Download full-text PDF

Source
http://dx.doi.org/10.3109/14992020903300431DOI Listing

Publication Analysis

Top Keywords

otoacoustic emissions
12
retest measurement
12
measurement probe-refitting
12
distortion product
8
product otoacoustic
8
probe-refitting retest
8
half-octave frequency
8
reliability
7
transient-evoked distortion
4
emissions short-term
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!