A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Energy expenditure of transfemoral amputees walking on a horizontal and tilted treadmill simulating different outdoor walking conditions. | LitMetric

Transfemoral amputees often report that walking on tilted pavements or on terrain with the prosthesis on the side of higher elevation is quite strenuous. This study investigates the energy expenditure of transfemoral amputees (n = 8) on a motorized treadmill, simulating different strenuous outdoor walking conditions. Oxygen uptake at self-selected speed of gait was measured during walking at three different treadmill positions: (i) Horizontal treadmill, (ii) 3% tilt in the sagittal plane and (iii) 3% tilt in both the sagittal and frontal plane of the treadmill. The difference in median values of oxygen uptake between position (i) and (ii) was 4.3%, and 16.4% between position (ii) and (iii) (p < or = 0.05, for both comparisons). The subjects utilized about 50% of their VO(2max) when walking in position (i) and (ii), with an increase to about 60% of their VO(2max) when walking in position (iii). Transfemoral amputees use significantly more energy when walking on a moderately tilted surface in the frontal plane compared to walking with a tilt in the sagittal plane. This is probably because the prosthetic leg becomes functionally too long when the walking surface is tilted sideways, and the transfemoral amputees adopt a more energy consuming gait pattern.

Download full-text PDF

Source
http://dx.doi.org/10.3109/03093640903585016DOI Listing

Publication Analysis

Top Keywords

transfemoral amputees
20
tilt sagittal
12
walking
10
energy expenditure
8
expenditure transfemoral
8
treadmill simulating
8
outdoor walking
8
walking conditions
8
oxygen uptake
8
sagittal plane
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!