Although there is no need for routine coagulation monitoring with rivaroxaban--an oral, direct factor Xa inhibitor--a haemostasis assay might be valuable to measure its pharmacodynamic effects. This study aimed to find assays, among those commercially available, to measure rivaroxaban pharmacodynamics. Several global conventional clotting tests, as well as clotting or chromogenic assays to measure anti-factor Xa activity, were studied. A thrombin generation test using calibrated automated thrombogram was also done. Tests were performed with the indirect factor Xa inhibitor fondaparinux for comparison. A concentration-dependent prolongation of prothrombin time (PT), dilute PT, and activated partial thromboplastin time was observed with rivaroxaban. The results varied depending on the reagents. This variability cannot be standardised with the international normalised ratio system commonly used for vitamin K antagonists. Using a standard calibration curve, PT test results can be expressed in plasma concentrations of rivaroxaban rather than PT seconds or ratio. Standard methods for HepTest and two-step prothrombinase-induced clotting time (PiCT) resulted in a paradoxical response, with low concentrations of rivaroxaban reducing clotting times. This was not observed with shorter incubation times, or when antithrombin-deficient (immunodepleted) plasma was used. The chromogenic tests found a dose-dependent relationship between anti-factor Xa activity and rivaroxaban concentration. Modified specific factor Xa chromogenic assays are being further investigated. One-step PiCT and HepTest with shortened incubation times, as well as the widely available PT assay (using a rivaroxaban calibrator) could be useful to monitor the pharmacodynamic effects of rivaroxaban accurately. Finally, all clotting and chromogenic assays showed a concentration-dependent effect induced by rivaroxaban.

Download full-text PDF

Source
http://dx.doi.org/10.1160/TH09-03-0176DOI Listing

Publication Analysis

Top Keywords

chromogenic assays
12
assays measure
8
rivaroxaban--an oral
8
oral direct
8
direct factor
8
factor inhibitor
8
pharmacodynamic effects
8
rivaroxaban
8
clotting chromogenic
8
anti-factor activity
8

Similar Publications

Background: Hemophilia B, or Christmas disease, is a hemorrhagic inherited disorder. Previous studies have reported measurement discrepancies in factor VIII activity between clot-based and chromogenic assays in approximately one-third of patients with non-severe hemophilia A. However, similar discrepancies in hemophilia B have been less extensively studied.

View Article and Find Full Text PDF

Recombinant Factor C as an In Vitro Assay for the Residual Pathogenicity Evaluation of Veterinary Autogenous Vaccines.

Vet Sci

December 2024

Istituto Zooprofilattico Sperimentale Dell'Umbria e Delle Marche "Togo Rosati", via G. Salvemini 1, 06126 Perugia, Italy.

Background: Veterinary autogenous vaccines, similar to all injectable pharmaceutical products, must be tested to assess endotoxin concentrations. The Limulus Amebocyte Lysate Test (LAL test) is widely used in in vitro quality control assays for endotoxin detection, although it presents some ethical issues related to the production of reagents and is also characterized by a low specificity due to other contaminants that can activate the reaction. For all these reasons, a new recombinant factor C LAL test was developed.

View Article and Find Full Text PDF

Choline Oxidase-Incorporated ATRP-Based Cerium Nanogels as Nanozymes for Colorimetric Detection of Hydrogen Peroxide and Choline.

Biosensors (Basel)

November 2024

Department of BioNano Technology, Gachon University, 1342 Seongnamdae-ro, Sujeong-gu, Seongnam 13120, Republic of Korea.

Choline is an important molecule in monitoring food safety and infant nutrition. Here, we report Ce nanogels synthesized by atom transfer radical polymerization (ATRP) employing Ce-coordinated acryloyl-lysine polymer brushes (Ce@SiO NGs) as highly efficient cascade nanozymes for colorimetric detection of choline. The synthesized Ce@SiO NGs demonstrated remarkable peroxidase-like activity with a porous exterior, which are essential to entrap choline oxidase (COx) to yield COx@Ce@SiO NGs and construct a cascade reaction system to detect choline.

View Article and Find Full Text PDF

Enhanced histopathology of the immune system uses a precise, compartment-specific, and semi-quantitative evaluation of lymphoid organs in toxicology studies. The assessment of lymphocyte populations in tissues is subject to sampling variability and limited distinctive cytologic features of lymphocyte subpopulations as seen with hematoxylin and eosin (H&E) staining. Although immunohistochemistry is necessary for definitive characterization of T- and B-cell compartments, routine toxicologic assessments are based solely on H&E slides.

View Article and Find Full Text PDF

Molecular and clinical characterization of two independent Chinese families with protein C deficiency.

Ann Hematol

December 2024

Department of Clinical Laboratory, Key Laboratory of Clinical Laboratory Diagnosis and Translational Research of Zhejiang Province, The First Affiliated Hospital of Wenzhou Medical University, Shangcai Village, Ouhai District, Wenzhou, 325000, China.

This study aims to investigate the clinical characterization and molecular pathogenic basis of hereditary protein C (PC) deficiency in two independent Chinese families, and conduct in vitro expression studies on the newly discovered p.Trp444Arg mutation. The PC activity (PC: A) was tested using the chromogenic substrate, and PC antigen (PC: Ag) was detected via enzyme-linked immunosorbent assay (ELISA).

View Article and Find Full Text PDF