Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: Thoracic pedicle screw fixation has many advantages over other methods of spinal fixation in treating various conditions. We evaluated the safety and efficacy of pedicle screw fixation in the thoracic spine.
Methods: We retrospectively reviewed 144 patients (65 males, 79 females; mean age 38 years; range 9 to 82 years) who underwent posterior thoracic pedicle screw instrumentation. A total of 827 thoracic pedicle screws were inserted to the thoracic spine (T1-12) by the same senior spine surgeon using the free-hand technique. Indications for thoracic spine surgery were deformities (n=47, 32.6%), metastatic or primary tumors (n=15, 10.4%), spinal infections (n=7, 4.9%), degenerative diseases (n=13, 9%), and spinal trauma (n=62, 43.1%). Screw containment was assessed by three independent reviewers on postoperative plain radiographs. In addition, thin-slice computed tomography scans were obtained in 21 suspected cases (29 screws).
Results: Screw containment was found in 94.3% (780 screws). Incorrect screw placement was found in 47 screws (5.7%), including 31 screws (3.8%) demonstrated by plain radiographs, and 16 screws (1.9%) demonstrated by thin-slice computed tomography scans. More than half of the faulty screws (n=24, 51.1%) were detected in scoliosis patients, especially on the concave side of the curvature (83.3%). The most frequent site of faulty screw placement was the T8 level (21.3%). No symptoms or complications occurred related to faulty screw placement.
Conclusion: The high accuracy of thoracic pedicle screw placement (94.3%) using the free-hand technique suggests that pedicle screw fixation of the thoracic spine is safe, reliable, and useful in the treatment of all types of spinal diseases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3944/AOTT.2009.522 | DOI Listing |