Currently-used mechanical and biological heart valve prostheses have several disadvantages. Mechanical prostheses, based on carbon, metallic and polymeric components, require permanent anticoagulation treatment, and their usage often leads to adverse reactions, e.g. thromboembolic complications and endocarditis. Xenogenous and allogenous biological prostheses are associated with immune reaction, thrombosis and degeneration, and thus they have a high rate of reoperation. Biological prostheses of autologous origin, such as pulmonary autografts, often burden the patient with a complicated surgery and the risk of reoperation. Therefore, efforts are being made to prepare bioartificial heart valves with an autologous biological component by methods of tissue engineering. They should be biocompatible, durable, endowed with appropriate mechanical properties and able to grow with a child. For this purpose, scaffolds composed of synthetic materials, such as poly(lactic acid), poly(caprolactone), poly(4-hydroxybutyrate), hydrogels or natural polymers, e.g. collagen, elastin, fibrin or hyaluronic acid, have been seeded with autologous differentiated, progenitor or stem cells. Promising results have been obtained with nanostructured scaffolds, and also with cultivation in special dynamic bioreactors prior to implantation of the bioartificial grafts into an animal organism.

Download full-text PDF

Source
http://dx.doi.org/10.33549/physiolres.931919DOI Listing

Publication Analysis

Top Keywords

heart valves
8
biological prostheses
8
tissue-engineered heart
4
valves currently-used
4
currently-used mechanical
4
biological
4
mechanical biological
4
biological heart
4
heart valve
4
prostheses
4

Similar Publications

We describe a 30-year-old Caribbean-Black woman with a clinical presentation suggestive of a transient ischemic attack (TIA) with no conventional cerebrovascular risk factors, albeit with a newly diagnosed quadricuspid aortic valve (QAV) with moderate aortic regurgitation (AR). Although QAV is a recognized congenital cardiac defect, its association with TIA remains elusive. This case highlights the importance of considering potential atypical etiologies, such as QAV, in the evaluation and management of young patients presenting with cerebrovascular events.

View Article and Find Full Text PDF

Some patients with aortic stenosis may require multiple valve interventions in their lifetime, and choosing transcatheter aortic valve replacement (TAVR) as the initial intervention may be appealing to many. If their transcatheter heart valve degenerates later in life, most will hope to undergo redo-TAVR. However, if redo-TAVR is not feasible, some may have to undergo surgical explantation of their transcatheter heart valve (TAVR-explant).

View Article and Find Full Text PDF

Severe aortic valve stenosis poses a significant risk for the aging population, often escalating from mild symptoms to life-threatening heart failure and sudden death. Without timely intervention, this condition can lead to disastrous outcomes. The advent of transcatheter aortic valve implantation (TAVI) has gained popularity, emerging as an effective alternative for managing severe aortic stenosis (AS) in high-risk patients experiencing deterioration of previously implanted bioprosthetic surgical aortic valves (SAV), which introduces complex challenges such as device compatibility and anatomical considerations.

View Article and Find Full Text PDF

Background: Vitamin K antagonists (VKA) continue to be the principal anticoagulants for both the treatment and prevention of venous thromboembolism. The use of VKA often requires regular monitoring to avoid over-anticoagulation and prevent thromboembolic complications. The aim was to determine the indication for VKA use and factors associated with suboptimal anticoagulation control among patients in northern Tanzania.

View Article and Find Full Text PDF

Use of Claims to Assess Outcomes and Treatment Effects in the Evolut Low Risk Trial.

Circ Cardiovasc Interv

January 2025

Richard A. and Susan F. Smith Center for Outcomes Research in Cardiology, Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA (C.L., A.T., Y.S., J.S., R.W.Y.).

Background: Food and Drug Administration-mandated postmarket studies for transcatheter aortic valve replacement in low-risk populations plan to use passively collected registry data linked to claims for long-term follow-up out to 10 years. Therefore, it is critically important to understand the validity of these claims-based end points. We sought to evaluate the ability of administrative claims with () codes to identify trial-adjudicated end points and reproduce treatment comparisons of aortic valve replacement in the Evolut Low Risk Trial.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!