A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Left-sided mouse intubation: description and evaluation. | LitMetric

Left-sided mouse intubation: description and evaluation.

Exp Lung Res

Internal Medicine V/Pulmonary Division, and Clinical and Experimental Surgery, University Hospital Homburg/Saar, University of Saarland, Germany.

Published: February 2010

A method of left main bronchus intubation was developed based on a wire guide-based microscopic endotrachael mouse intubation technique. The authors used a 22 G x 1 inch catheter elongated by a 38-mm silicone tube, and a wire guide with a tag to assign the length of the wire completely covered by the silicon tube. The isoflurane-anesthetized mouse was hung perpendicularly with its incisors on a thread and transorally intubated under strict vision with the wire guide tip advanced 3 mm out of the catheter. Then the catheter was advanced about 6 to 8 mm into the trachea. Afterwards the wire guide was redrawn to the level of the catheter tip (blue tag on the wire guide appeared at the upper end of catheter) to prevent injury. Then the neck was pushed into a right lateral flexion with one finger against a foam block fixed on the vertical plate, causing a straight distance between mouth and left main bronchus. This positioning allows to gently advance the catheter into the left main bronchus by another about 20 mm, using the wire guide with its tip just within the tube, to achieve there a wedge position with gentle pressure.The technique had a success rate of more than 80% in 81 mice weighing 23 to 48 g. It may be of interest for unilateral lung intervention, e.g., with injurious substances or with drugs.

Download full-text PDF

Source
http://dx.doi.org/10.3109/01902140903042597DOI Listing

Publication Analysis

Top Keywords

wire guide
20
left main
12
main bronchus
12
mouse intubation
8
wire
7
catheter
6
guide
5
left-sided mouse
4
intubation description
4
description evaluation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!