A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment and comparison of anterior chamber dimensions using various imaging techniques. | LitMetric

Assessment and comparison of anterior chamber dimensions using various imaging techniques.

Ophthalmic Surg Lasers Imaging

Yeditepe University Eye Hospital, Sakir Kesebir Sokak No:28 Balmumcu, Besiktas, 34349 Istanbul, Turkey.

Published: March 2010

Background And Objective: To assess and compare the horizontal dimensions of the anterior chamber by different anterior segment imaging techniques.

Patients And Methods: Eighty eyes of 40 patients without any ocular disease or previous ocular surgery were recruited and three consecutive measurements of internal anterior chamber diameter and white-to-white distance (WTW) parameters were determined.

Results: Mean internal anterior chamber diameter was 11.80 +/- 0.39, 11.56 +/- 0.47, and 11.61 +/- 0.58 mm with Visante-OCT, SL-OCT, and Pentacam, respectively. Mean WTW distance was 11.87 +/- 0.35 and 11.65 +/- 0.32 mm by IOLMaster and OrbscanIIz, respectively. There was no significant difference between Visante-OCT and Pentacam, IOLMaster, and OrbscanIIz (P = .125, .918, and .314). However, detection of mean internal anterior chamber diameter was significantly greater by Visante-OCT than SL-OCT (P = .026). All devices displayed a high intrasession repeatability (repeated measured ANOVA, P > .05).

Conclusion: Internal anterior chamber diameter measurements using Visante-OCT, SL-OCT, and Pentacam, and WTW measurements using IOLMaster and OrbscanIIz were easy to handle and demonstrated good repeatability. Although similar results of horizontal anterior chamber diameter were determined by Visante-OCT, Pentacam, IOLMaster, and OrbscanIIz, the inter-device differences should be considered during clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.3928/15428877-20091230-21DOI Listing

Publication Analysis

Top Keywords

anterior chamber
28
chamber diameter
20
internal anterior
16
iolmaster orbscaniiz
16
visante-oct sl-oct
12
anterior
8
sl-oct pentacam
8
pentacam wtw
8
visante-oct pentacam
8
pentacam iolmaster
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!