A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A prospective multicenter cohort study of the association between global tissue hypoxia and coagulation abnormalities during early sepsis resuscitation. | LitMetric

Objective: Coagulation activation is an integral part of sepsis pathogenesis. Experimental data suggest that endothelial exposure to hypoxia activates coagulation. We aimed to test the hypothesis that the quantity of exposure to global tissue hypoxia is associated with the degree of coagulation activation during early sepsis resuscitation.

Design: Prospective, multicenter cohort study.

Setting: Emergency department and intensive care unit of three academic hospitals.

Patients: Inclusion criteria were age older than 17, acute infection with two or more signs of systemic inflammation, hypotension despite fluid challenge (or lactate >4 mM), and continuous central venous oxygen saturation (Scvo2) monitoring for quantitative resuscitation. Exclusion criteria were anticoagulant or blood product administration.

Measurements And Main Results: We recorded central venous oxygen saturation continuously for 0 to 6 hrs of resuscitation and calculated the area under the curve for central venous oxygen saturation <70%. We defined hypoxia exposure as exceeding the median area under the curve for the entire cohort. At 0, 6, and 24 hrs, we measured conventional coagulation biomarkers plus thrombin-antithrombin complex, plasmin-antiplasmin complex, tissue plasminogen activator, plasminogen activator inhibitor-1, protein C, antithrombin, and endothelial markers (E-selectin, intracellular adhesion molecule-1, thrombomodulin). We compared changes during 0 to 6 hrs and 0 to 24 hrs in biomarkers between hypoxia exposure and nonexposure groups. We enrolled 40 patients (60% requiring vasopressors; 30% mortality). We found that exposure to hypoxia alone was not associated with a significant degree of coagulation activation. However, in secondary analyses we found that exposure to arterial hypotension induced E-selectin and thrombin-antithrombin complex, whereas concomitant exposure to both hypotension and hypoxia was associated with amplification of E-selectin and thrombomodulin, and a reduction in protein C.

Conclusion: In this sample of patients undergoing quantitative resuscitation for sepsis, we found that exposure to global tissue hypoxia (as quantified by low central venous oxygen saturation) was not associated with major coagulation activation. Further investigation to elucidate the clinical factors that trigger or intensify the procoagulant response to sepsis is warranted.

Download full-text PDF

Source
http://dx.doi.org/10.1097/CCM.0b013e3181cf6fbcDOI Listing

Publication Analysis

Top Keywords

central venous
12
venous oxygen
12
oxygen saturation
12
prospective multicenter
8
multicenter cohort
8
global tissue
8
tissue hypoxia
8
early sepsis
8
coagulation activation
8
cohort study
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!