Objective: The aim of this study was to evaluate the flow rate of 3 endodontic sealers: Sealer 26, AH Plus, and MTA Obtura.

Study Design: According to the method proposed by the American Dental Association (ADA specification no. 57), the sealers were placed between 2 glass slabs under a weight of 120 g. The diameters of the formed discs were measured with a digital paquimeter. The test was repeated 5 times for each sealer.

Results: The results were expressed as arithmetic means, and the statistical analysis was performed through Turkey test. AH Plus showed significantly superior flow rate compared with Sealer 26 and MTA Obtura. There was no statistically significant difference between flow rates presented by Sealer 26 and MTA Obtura.

Conclusion: Within the limitations of this in vitro study, it was concluded that all of the the endodontic sealers tested presented greater flow than the minimum recommended in the ADA 57 specification.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.tripleo.2009.08.038DOI Listing

Publication Analysis

Top Keywords

sealer mta
16
flow rate
12
endodontic sealers
12
rate endodontic
8
sealers sealer
8
mta obtura
8
ada specification
8
evaluation flow
4
sealers
4
sealer
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!