Objective: To study a rapid Xpert polymerase chain reaction (PCR) method in detecting methicillin-resistant Staphylococcus aureus (MRSA) in patients and healthcare workers (HCW) exposed to MRSA, and to estimate savings associated to isolation or work restriction.
Methods: A test set of four double (one for the growth and one for the rapid test) pre-wet swabs from the nose, throat, hands/wrists and perineum was studied by a growth method and by the Xpert MRSA test.
Results: The total correspondence between the growth and the rapid test was 92.8%. The overall sensitivity, specificity, positive and negative predictive values were for the Xpert MRSA test: 87%, 99.6%, 68.5% and 99.9%, and for the growth test: 76%, 100%, 100%, and 99.8%, assuming a prevalence of MRSA of 0.01%. Among the MRSA positive persons, the Xpert and growth tests detected MRSA in 44.6% and 40% of nose samples, respectively, 38.2% and 45.5% throat samples, 30.8% and 11.5% hands/wrists samples, 44% and 38% perineum samples, and in 81.8% and 77.3% wound samples, respectively. By combining four anatomical sites, the detection rate increased to 87.5% by both methods. The cost for each Xpert and growth test was euro50 and euro6.25, respectively. The rapid test would save at least euro925 per exposed HCW and euro550 per patient that were MRSA negative.
Conclusion: The MRSA Xpert test is easy to perform, has a high negative predictive value, and may be used to control healthcare workers and patients exposed to MRSA. Sampling from multiple anatomical locations is recommended. Still, more then 10% of MRSA positive cases may not be found.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jinf.2010.01.008 | DOI Listing |
JMIR Mhealth Uhealth
January 2025
Department of Learning and Workforce Development, The Netherlands Organisation for Applied Scientific Research, Soesterberg, Netherlands.
Background: Wearable sensor technologies, often referred to as "wearables," have seen a rapid rise in consumer interest in recent years. Initially often seen as "activity trackers," wearables have gradually expanded to also estimate sleep, stress, and physiological recovery. In occupational settings, there is a growing interest in applying this technology to promote health and well-being, especially in professions with highly demanding working conditions such as first responders.
View Article and Find Full Text PDFNat Biomed Eng
January 2025
School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, Singapore, Singapore.
The utility of urinary tests for the monitoring of the treatment efficacy and adverse events of anticancer therapies is constrained by the low concentration of relevant urinary biomarkers. Here we report, using mice with lung cancer and treated with chemotherapy, of a urinary fluorescence test for the concurrent monitoring of the levels of a tumour biomarker (cathepsin B) and of a biomarker of chemotherapy-induced kidney injury (N-acetyl-β-D-glucosaminidase). The test involves two intratracheally administered urinary reporters leveraging caged bioorthogonal click handles for the biomarker-dependent activation of 'clickability' and renal clearance, and the bioorthogonal click reaction of each renally cleared reporter with paired fluorescence indicators in the collected urine.
View Article and Find Full Text PDFAnal Chem
January 2025
Center of Clinical Laboratory Medicine, Zhongda Hospital, Medical School of Southeast University, Nanjing 210009, Jiangsu, China.
The incidence of cervical cancer continues to rise in underdeveloped regions due to low human papillomavirus (HPV) vaccination rates and inadequate screening systems. To achieve convenient, rapid, and accurate detection of HPV, we developed a three-wire lateral flow strip assay system based on dual-OR logic gates for rapid and simultaneous detection of HPV subtypes 16 and 18 in a single test. The system combines three-branch-catalytic hairpin assembly (TCHA)-mediated signal amplification with simple OR logic gate-based signal output to improve detection rates while enabling HPV 16/18 subtype identification.
View Article and Find Full Text PDFAnal Chim Acta
March 2025
The Radiology Department of Shanxi Provincial People's Hospital Affiliated to Shanxi Medical University, Taiyuan, 030001, China. Electronic address:
Background: Real-time and rapid detection of ingredients in food has important significance for food safety. However, traditional detection methods not only require bulky and costly instruments but also are often based on single-mode analysis, limiting their accuracy and applications in point-of-care testing. Herein, an integrated and miniaturized dual-mode device based on colorimetric and photoacoustic (PA) principles is developed, using Au@Ag nanoparticles (Au@AgNPs) as signal probe and ascorbic acid (AA) and ascorbate oxidase (AAO) as analytes.
View Article and Find Full Text PDFInt J Cardiol
January 2025
Department of Computer Center, Zigong Fourth People's Hospital, Zigong, Sichuan 643000, China.
Background: Acute Stanford Type A aortic dissection (AAD-type A) and acute myocardial infarction (AMI) present with similar symptoms but require distinct treatments. Efficient differentiation is critical due to limited access to radiological equipment in many primary healthcare. This study develops a multimodal deep learning model integrating electrocardiogram (ECG) signals and laboratory indicators to enhance diagnostic accuracy for AAD-type A and AMI.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!