Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Study Objective: To investigate the efficacy of preoxygenation by eight deep breaths in 60 seconds with the Mapleson A (Magill) system, the circle anesthesia system, or the Mapleson D system at an oxygen flow of 5 L/min or 10 L/min.
Design: Randomized, clinical study.
Setting: Operating room of a university hospital.
Subjects: 10 healthy volunteers.
Interventions: Volunteers underwent 6 preoxygenation trials consisting of 8 deep breaths in 60 seconds using the Mapleson A, Mapleson D, and the circle anesthesia systems at an oxygen flow of 5 L/min and 10 L/min.
Measurements: Fractional end-tidal oxygen concentration (F(ET)O(2)) was measured at 15-second intervals during preoxygenation.
Results: At an oxygen flow of 10 L/min, mean F(ET)O(2) values at 60 seconds of preoxygenation were comparable among the Mapleson A, Mapleson D, and the circle anesthesia systems (87 +/- 2.1%, 87 +/- 1.6%, 87 +/- 1.6%, respectively). Using an oxygen flow of 5 L/min, mean F(ET)O(2) values at 60 seconds were similar among the Mapleson A, Mapleson D, and circle anesthesia systems (74 +/- 4.1%, 75 +/- 2.6%, 74 +/- 4.4%, respectively); however, they were significantly lower than the corresponding values achieved at an oxygen flow of 10 L/min.
Conclusions: The 8-deep-breaths in 60 seconds technique at an oxygen flow of 10 L/min can achieve adequate preoxygenation with the Mapleson A (Magill), Mapleson D, and circle anesthesia systems. Suboptimal preoxygenation is obtained with the three systems when the oxygen flow used is 5 L/min.