Purpose: This study was designed to evaluate radiocontrast-induced nephrotoxicity (RIN), and the image quality and findings of venography using small doses of radiocontrast as a venous mapping method in pre-dialysis patients.

Methods: Twenty-eight patients with stage 4 and 5 chronic kidney disease underwent arm venography with 10-15 ml of dilute contrast medium. Image quality, venographic findings and glomerular filtration rate (GFR) before and after the procedure were evaluated.

Results: Mean GFR was 19.3+/-5.8 ml/min/1.73 m2 (7-30 ml/min/1.73 m2). Image quality of venography in the forearm and upper arm veins was good in all patients. Central veins were visualized well in 26 (92.8%) patients. Eight (28.5%) patients showed cephalic veins inadequate for creation of radiocephalic arteriovenous fistula (AVF) because of occlusion or small diameter veins. There was no significant difference in GFR between the pre- and post-study (19.3+/-5.8 vs. 19.2+/-6.2 ml/min/1.73 m2, p=0.693). RIN developed (GFR: 17 to 13 ml/min/1.73 m2) in only one patient but without sequelae, and the GFR completely recovered to baseline level 7 days after the study.

Conclusion: Small dose venography is safe and effective for venous mapping in pre-dialysis patients.

Download full-text PDF

Source
http://dx.doi.org/10.1177/112972981001100207DOI Listing

Publication Analysis

Top Keywords

venous mapping
12
image quality
12
small dose
8
patients
6
venography
5
gfr
5
small
4
dose contrast
4
contrast venography
4
venography venous
4

Similar Publications

Fontan-associated liver disease (FALD) may be caused by chronic liver congestion due to high central venous pressure (CVP). Recently, the usefulness of liver native T1 mapping in magnetic resonance imaging (MRI) in adulthood has been reported. To evaluate the usefulness of native liver T1 mapping in children with congenital heart disease (CHD), we investigated the utility of native liver T1 relaxation time (LT1) in pediatric Fontan patients in comparison to other CHDs.

View Article and Find Full Text PDF

Background: Evidence-based venous thromboembolism prevention and management is a priority for global health services. Low adoption of venous thromboembolism guidelines can result in compromised patient outcomes. Understanding clinicians' and patients' perceptions of barriers to and facilitators for guideline implementation and mapping identified barriers and facilitators to the Consolidated Framework for Implementation Research may inform theoretical interventions to improve guideline adoption rates.

View Article and Find Full Text PDF

Intravascular Sympathetic Stimulation to Facilitate Catheter Ablation of Premature Ventricular Complexes.

JAMA Cardiol

December 2024

Section for Cardiac Electrophysiology, Division of Cardiovascular Medicine, Department of Medicine, University of Pennsylvania, Philadelphia.

Importance: Infrequent intraprocedural premature ventricular complexes (PVCs) limit the efficacy of catheter ablation. Intravascular stimulation of sympathetic nerves via vertebral veins (VVs) has been used to activate cardiac sympathetic tone and may promote PVCs.

Objective: To characterize the ability of direct electrical sympathetic stimulation via VVs to induce PVCs at the time of catheter ablation.

View Article and Find Full Text PDF

Aim: Our objective was to determine the factors associated with the successful maturation of arteriovenous fistulas during hemodialysis.

Material And Methods: This prospective study included patients treated with hemodialysis and predialysis patients. Clinical, biochemical, sociodemographic, vascular ultrasound mapping, flow-mediated dilatation, and surgical factors were analyzed.

View Article and Find Full Text PDF

Introduction: Pulsed-field ablation (PFA) is a novel modality for pulmonary vein isolation in patients with atrial fibrillation (AF). We describe the initial uptake and experience of PFA using a pentaspline catheter across selected National Health Service England (NHSE) centres.

Methods: Data collected by NHSE Specialised Services Development Programme regarding AF ablation procedures using a single-shot, pentaspline, multielectrode PFA catheter (FARAWAVE, Boston Scientific) between June 2022 and August 2024 were aggregated and analysed to examine procedural metrics, acute efficacy and safety outcomes over 3-month follow-up.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!