The authors present a case of pericardial effusion that was percutaneously drained using agitated saline for echocardiographic contrast guidance. This technique can safely confirm the location of a pericardiocentesis needle in the pericardial space prior to tract dilation and insertion of the pericardial drainage catheter. In this instance, this technique prevented the inadvertent placement of the pericardiocentesis catheter in the right ventricle.