AI Article Synopsis

  • Endothelial microparticles (EMP) are potential biomarkers for diseases due to their release during endothelial disturbances, but their measurement methods need standardization.
  • A study analyzed the impact of different centrifugation speeds and storage conditions on EMP levels in samples from healthy volunteers, finding significant variations in counts depending on these factors.
  • The results highlight that EMP detection results can differ based on the protocols used, emphasizing the need for consistency in research methods to ensure reliable comparisons across studies.

Article Abstract

Introduction: Endothelial microparticles (EMP) are released into the circulation in case of endothelial disturbance, and are therefore increasingly investigated as a biomarker reflecting disease activity. Numerous pre-analytic methods have been proposed for their flow cytometric enumeration, but standardization is still lacking. In this study we evaluated the influence of centrifugation and storage conditions on EMP quantification.

Materials And Methods: Platelet-poor plasma (PPP) from 10 healthy volunteers was prepared by centrifugation at 1,550 g for 20 minutes twice. A first aliquot of PPP was analyzed immediately, a second after storage at 4 degrees C for 7 hours. A third and fourth aliquot were snap-frozen and stored at -80 degrees C for 7 and 28 days. A final aliquot was further centrifuged at 10,000g for 10 minutes and analyzed immediately. EMP were defined as CD31+CD42b-, CD62E+, CD144+ or CD144+CD105+ particles, smaller than 1.0 microm.

Results: High speed centrifugation led to a significant loss of CD31+CD42b- EMP (p=0.004). A good correlation between PPP and high speed centrifuged PPP was only found for CD144+ EMP (Kendall tau b=0.611, p=0.025). Storage at 4 degrees C did not affect EMP quantification. However, freezing at -80 degrees C increased CD31+CD42b- and CD62E+ EMP counts, and lowered CD144+ EMP (p<0.05). Nevertheless, the agreement among the different storage conditions was relatively good (Kendall coefficient of concordance >0.487; p<0.05).

Conclusion: The flow cytometric detection of EMP varies with the centrifugation protocol and the storage method used, and these changes also depend on the phenotype studied. The results of this study caution against comparing study results gathered with different EMP laboratory protocols.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.thromres.2009.12.019DOI Listing

Publication Analysis

Top Keywords

emp
9
flow cytometric
8
endothelial microparticles
8
microparticles emp
8
centrifugation storage
8
storage degrees
8
-80 degrees
8
cd31+cd42b- cd62e+
8
high speed
8
cd144+ emp
8

Similar Publications

Micellar liquid chromatography (MLC) has proven beneficial efficiency and ecological impact for routine quality control activities. In the proposed study, cyrene was investigated for the first time, together with other green additives, as a novel safe organic solvent in reversed-phase MLC. Quality-by-design (QbD) approach screened their effect on the separation performance.

View Article and Find Full Text PDF

Most blood cells derive from hematopoietic stem cells (HSCs), originating from endothelial cells. The induction of HSCs from endothelial cells occurs during mid-gestation, and research has revealed multiple steps in this induction process. Hemogenic endothelial cells emerge within the endothelium, transition to hematopoietic cells (pre-HSCs), and subsequently mature into functional HSCs.

View Article and Find Full Text PDF

Background: Two studies were conducted assessing the efficacy of NexGard® PLUS (NP) in preventing heartworm disease. Study 1 evaluated the efficacy of six monthly doses of NP or Simparica Trio® (ST) against a macrocyclic lactone-resistant isolate of heartworm, Dirofilaria immitis, and study 2 evaluated the efficacy of a single dose of NP against a susceptible isolate.

Methods: In two studies, dogs that were negative for heartworms by antigen test and modified Knott's test were used.

View Article and Find Full Text PDF

Pancreatic ductal adenocarcinoma (PDAC) has an extremely poor prognosis, due in part to early invasion and metastasis, which in turn involves epithelial-mesenchymal transition (EMT) of the cancer cells. Prompted by the discovery that two PDAC cell lines of the quasi-mesenchymal subtype (PANC-1, MIA PaCa-2) exhibit neuroendocrine differentiation (NED), we asked whether NED is associated with EMT. Using real-time PCR and immunoblotting, we initially verified endogenous expressions of various NED markers, i.

View Article and Find Full Text PDF

Toxin-antitoxin (TA) modules are important mediators of persister cell formation in response to environmental stresses. However, the mechanisms through which persistence is controlled remain poorly understood. , a novel probiotic, can enter a persistent state upon exposure to tetracycline stress.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!