Objective: To determine the minimal electric threshold (MET) of neurostimulation in and out of the lumbosacral epidural space necessary to cause muscle contraction of the hind limb or tail, determine an MET cutoff value that indicates epidural needle placement, and compare predictability of epidural needle placement attained by use of neurostimulation versus the standard technique that uses loss of resistance in dogs.
Animals: 96 healthy Beagles.
Procedures: Dogs received nonionic contrast medium (90 mg/kg) either in or out of the epidural space. Correct placement of the needle was evaluated by use of neurostimulation and loss of resistance of injection and confirmed by use of epidurography.
Results: With the neurostimulator test, MET was significantly lower in dogs with needle placement in the epidural space (mean +/- SEM, 0.30 +/- 0.07 mA) than those with needle placement out of the epidural space (1.2 +/- 0.13 mA). When an electric current cutoff of < or = 0.28 mA for the neurostimulator test was used to suggest correct needle placement in the lumbosacral epidural space, sensitivity and specificity were 74% and 93%, respectively. The loss of resistance test had sensitivity of 63% and specificity of 90%. The combination of both tests yielded a sensitivity of 89% and specificity of 83%.
Conclusions And Clinical Relevance: Neurostimulation is a useful tool to suggest correct lumbosacral epidural needle placement in dogs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2460/ajvr.71.2.157 | DOI Listing |
J Laparoendosc Adv Surg Tech A
January 2025
Department of Surgical Disciplines, All India Institute of Medical Sciences, New Delhi, India.
Laparo-endoscopic hernia surgery is recommended by various international bodies. However, its uptake by general surgeon is low. We aim to assess the impact of Three Dimensional (3D) endovision system in learning laparoscopic transabdominal preperitoneal (TAPP) repair of groin hernia and transferability of skills acquired from 3D to the Two Dimensional (2D) environment.
View Article and Find Full Text PDFTech Vasc Interv Radiol
December 2024
Department of Interventional Radiology, MedStar Georgetown University Hospital, Washington, DC. Electronic address:
Artificial intelligence and robotics are transforming interventional radiology, driven by advancements in computer vision, robotics and procedural automation. Historically focused on diagnostics, AI now also enhances procedural capabilities in IR, enabling future robotic systems to handle complex tasks such as catheter manipulation or needle placement with increasing precision and reliability. Early robotic systems in IR demonstrated improved accuracy in both vascular and percutaneous interventions, though none were equipped with automatic decision-making.
View Article and Find Full Text PDFTech Vasc Interv Radiol
December 2024
Department of Interventional Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, FL; Department of Interventional Radiology, Miami Cardiac and Vascular Institute, Baptist Health South Florida, Miami, FL; Department of Radiology and Nuclear Medicine, Amsterdam UMC, Location VUmc, Cancer Center Amsterdam, AMS, The Netherlands. Electronic address:
Robotic systems for minimally invasive procedures, particularly in interventional oncology, have advanced significantly, especially for percutaneous interventions guided by CT, Cone-beam CT, and MRI. These systems, which include needle-guiding and needle-driving robots, enhance the precision of procedures like biopsy and tumor ablation. Needle-guiding robots plan and align the needle, while needle-driving robots autonomously advance it, improving needle placement accuracy, enabling out-of-plane insertion, and reducing radiation exposure.
View Article and Find Full Text PDFTech Vasc Interv Radiol
December 2024
Interventional Radiology Service, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY; Department of Radiology, Weill Cornell Medical College, New York, NY. Electronic address:
Interventional radiology (IR) has aided advances in the diagnosis and treatment of lung pathologies through procedures such as percutaneous biopsy, tumor ablation and drainage of intra-thoracic collections. The success and safety of these interventions largely depend on timely and accurate needle/device placement. Additionally, there is an inherent need to minimize radiation exposure during image-guided procedures.
View Article and Find Full Text PDFJ Pediatr Urol
January 2025
Ege University, Faculty of Medicine, Department of Pediatric Surgery, Division of Pediatric Urology, TÜRKİYE.
Introduction: The guidelines lack clarity on how to follow the patients after endoscopic treatment for vesicoureteral reflux (VUR). The most discussed question is the need for voiding cystourethrogram (VCUG). Risk-based approaches that consider patient characteristics, disease severity, or factors related to the surgery itself could reduce its use, but a satisfactory predictive model has not yet been established.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!