A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1036
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3154
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy and precision of HDL cholesterol measurements using an office chemistry analyzer. | LitMetric

Background: A physician can obtain a patient's complete lipoprotein profile at the time of the office visit including assays of the total serum cholesterol, high-density lipoprotein cholesterol (HDL-C), and fasting triglyceride concentrations, and then calculate the low-density lipoprotein cholesterol (LDL-C). Until recently, this was not possible. Instruments are currently available that provide reliable rapid total serum cholesterol and fasting triglyceride measurements.

Methods: This study evaluated the accuracy and precision of a recently developed analytical method for the rapid measurement of HDL-C (Seralyzer Cholesterol System) as compared with a reference clinical laboratory method (Kodak Ektachem 700 XR). Blood specimens were taken from 90 participants and were analyzed in duplicate for HDL-C concentrations and total cholesterol using the Seralyzer and a standard Ektachem 700 XR.

Results: Nearly all (98.9%) of the initial Seralyzer HDL-C measures were within +/- 0.08 mmol/L (+/- 3 mg/dL) of the duplicate Seralyzer values. Most (98.3%) of the Seralyzer HDL-C results were within +/- 0.16 mmol/L (+/- 6 mg/dL) of the Kodak HDL-C values.

Conclusions: The Seralyzer HDL-C test provides a reliable and accurate measure of the HDL-C concentration.

Download full-text PDF

Source

Publication Analysis

Top Keywords

seralyzer hdl-c
12
accuracy precision
8
total serum
8
serum cholesterol
8
lipoprotein cholesterol
8
hdl-c
8
fasting triglyceride
8
ektachem 700
8
mmol/l +/-
8
+/- mg/dl
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!