Aim: To assess the effect of cine frame rate on the accuracy of the detection of pulmonary nodules at computed tomography (CT).

Materials And Methods: CT images of 15 consecutive patients with (n = 13) or without (n = 2) pulmonary metastases were identified. Initial assessment by two thoracic radiologists provided the "actual" or reference reading. Subsequently, 10 radiologists [board certified radiologists (n = 4) or radiology residents (n = 6)] used different fixed cine frame rates for nodule detection. Within-subjects analysis of variance (ANOVA) was used to evaluate the data.

Results: Eighty-nine nodules were identified by the thoracic radiologists (median 8, range 0-29 per patient; median diameter 9 mm, range 4-40 mm). There was a non-statistically significant trend to reduced accuracy at higher frame rates (p=0.113) with no statistically significant difference between experienced observers and residents (p = 0.79).

Conclusion: The accuracy of pulmonary nodule detection at higher cine frame rates is reduced, unrelated to observer experience.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.crad.2009.05.016DOI Listing

Publication Analysis

Top Keywords

cine frame
16
frame rates
12
accuracy detection
8
detection pulmonary
8
pulmonary nodules
8
frame rate
8
thoracic radiologists
8
nodule detection
8
frame
5
observer accuracy
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!