A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dosimetric impact of surgical clips in electron beam treatment of breast cancer. | LitMetric

Titanium clips are commonly used to delineate the location of the tumor bed during breast cancer surgery. Electron beams are frequently used to boost radiation dose to the breast cavity. This research investigated the effect on such boost treatments as a result of metallic clip perturbation potentially exhibited through attenuation and scatter processes using measurements with Gafchromic film and treatment planning simulation with both generalized Gaussian pencil beam and electron Monte Carlo algorithms. Results showed that the potential effect of clip interference is unidentifiable from both algorithms. Dosimetry with Gafchromic external beam therapy film did detect dose perturbations caused by the titanium clips in proximal plane, 0.23 mm away, resulting in 3.0% backscatter and 2.4% attenuation at 6 MeV and 2.0% backscatter and 6.7% attenuation at 9 MeV. The noise contribution of the film scanner is estimated to be about 0.4% and nearly 2% uncertainty in film calibration. As a result, we conclude that the magnitude of dose perturbations from clip is negligible for clinical findings.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.meddos.2009.12.003DOI Listing

Publication Analysis

Top Keywords

breast cancer
8
titanium clips
8
dose perturbations
8
attenuation mev
8
dosimetric impact
4
impact surgical
4
surgical clips
4
clips electron
4
electron beam
4
beam treatment
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!