Diagnostic reference levels in pediatric radiology in Austria.

Eur Radiol

Center for Biomedical Engineering and Physics, Medical University of Vienna, Vienna, Austria.

Published: July 2010

Background: Because of the higher sensitivity to radiation in children, optimization plays an essential role in pediatric radiology. Diagnostic reference levels are a helpful tool to optimize patient dose for standard radiographic procedures.

Methods: A nationwide survey was conducted to determine doses and variation in average dose applied to children for standard X-ray examinations. Dose values for chest, skull and abdomen X-ray procedures were determined for newborns, 1, 5, 10 and 15 year olds.

Results: Third quartiles of patient doses are provided and compared to European, British and German reference values. Variation in average doses between hospitals (i.e., ratio of maximal to minimal applied average dose) for the same age and examination was found to be typically a factor of eight. Ratios of maximal to minimal applied doses to individual patients were found to be approximately a factor of six higher than variations of average doses between clinics.

Conclusions: While average patient doses indicate the use of good radiological practice in general, variance in average doses applied by different hospitals indicate that audit of dose with respect to reference values will provide guidance for optimization. Such practice should result in lowering doses for pediatric examinations.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-009-1697-7DOI Listing

Publication Analysis

Top Keywords

average doses
12
diagnostic reference
8
reference levels
8
pediatric radiology
8
doses
8
variation average
8
average dose
8
patient doses
8
reference values
8
maximal minimal
8

Similar Publications

To explore the changes and significance of resolvin D1 (RvD1) in the treatment of systemic lupus erythematosus (SLE) with Belimumab. The clinical data from patients with moderate to severe disease activity SLE who received oral stable doses of glucocorticoids (≤10 mg/d) and/or immunosuppressants for more than 3 months at the outpatient or inpatient department of the First Affiliated Hospital of Soochow University from January 2022 to November, 2023 were retrospectively collected. All patients were treated with 10 mg/kg intravenous infusion of Belimumab.

View Article and Find Full Text PDF

One of the most problematic goals for radiation safety during spaceflight is an assessment of additional doses received by astronauts during extravehicular activity (EVA). The Pille-ISS thermoluminescent dosimeter developed by the predecessor of the Hungarian Research Network (HUN-REN) Centre for Energy Research (Budapest, Hungary) is designed for the routine dose measurements not only inside the spacecraft compartments, but also for personal dosimetric control for EVA. During almost two decades of the International Space Station (ISS) operation, the unique set of 131 EVA doses were recorded in different conditions, such as: solar activity, ISS trajectory along the South Atlantic Anomaly (SAA), and shielding conditions provided by two kinds of spacesuits: the Extravehicular Mobility Unit (EMU) and Orlan.

View Article and Find Full Text PDF

Introduction: Antimicrobial resistance (AMR) is a major public health challenge globally. This study aimed to analyze the antibacterial consumption (ATBc), and the incidence of multidrug-resistant organisms (MDRO), focusing on pathogens Enterococcus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, and Enterobacter spp. (ESKAPE group), in a Brazilian tertiary care hospital.

View Article and Find Full Text PDF

Background And Objectives: Faricimab, a bispecific antibody targeting VEGF-A and angiopoietin-2, has shown promise in treating neovascular age-related macular degeneration (nAMD). This study evaluates 1-year outcomes of faricimab in treatment-experienced nAMD patients.

Methods: This single-centre retrospective cohort study included patients previously treated for nAMD who switched to faricimab between November 2022 and March 2024.

View Article and Find Full Text PDF

Background: Moderate-to-severe pain is common after cardiac surgery, peaking during the first and second postoperative days. Several nerve blocks for sternotomy have been described; however, the optimal location for continuous catheters has not been established. This study assessed the feasibility of a larger trial evaluating the efficacy of serratus anterior plane (SAP) catheter analgesia for sternotomy pain.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!