In this study, we show for the first time that the separation efficiency of a pillar array column under pressure-driven liquid chromatography (LC) conditions can be improved using a separation channel with low-dispersion turns. The pillar array column was fabricated by reactive ion etching of a silicon substrate. With the low-dispersion-turn geometry, a column with a length and width of 110 mm and 400 microm, respectively, could be fabricated on a 20 x 20 mm microchip. Under nonretained conditions, the solute bands obtained for fluorescent compounds remained almost unchanged even after passing through the low-dispersion turns; however, significant skewing of the solute bands was observed in the case of constant-radius turns. Two coumarin dyes were well resolved under reversed-phase conditions, and a maximum theoretical plate number of 8000 was obtained. Successful separation of the fluorescent derivatives of six amino acids was achieved in 140 s. These results indicated that the separation efficiency of microchip chromatography could be significantly improved using a long separation channel with low-dispersion turns.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac902491xDOI Listing

Publication Analysis

Top Keywords

low-dispersion turns
16
pillar array
12
array column
12
pressure-driven liquid
8
liquid chromatography
8
separation efficiency
8
separation channel
8
channel low-dispersion
8
solute bands
8
turns
5

Similar Publications

To realize efficient, fast separations on pillar array columns with turns, a novel turn with low-dispersion and low-pressure-drop properties was developed. This "pillar-distribution-controlled" (PDC) turn was designed as a constant-radius turn filled with octagonal pillars that were arranged to control the linear velocity of the mobile phase in the radial direction. After the pillar positions were adjusted by computational fluid dynamics analysis, 27 mm long pillar array columns with two turns were fabricated on a 20 × 20 mm(2) silicon glass plate.

View Article and Find Full Text PDF

This study reports a fast and quantitative determination method for phenylalanine (Phe) and tyrosine (Tyr) in human plasma using on-chip pressure-driven liquid chromatography. A pillar array column with low-dispersion turns and a gradient elution system was used. The separation of fluorescent derivatives of Phe, Tyr, and other hydrophobic amino acids was successfully performed within 140 s.

View Article and Find Full Text PDF

Measurement of biological compounds is important for the clarification of biological phenomena. For the quantification of trace amounts of biological compounds, efficient separation and sensitive analytical methods are necessary. The present author developed HPLC-fluorescence and chemiluminescence detection methods for biological compounds such as catecholamines, amino acids, and thiols.

View Article and Find Full Text PDF

In this study, a fast and quantitative determination method for branched-chain amino acids (BCAAs), namely leucine, isoleucine, and valine, was developed using a pillar array column. A pillar array column with low-dispersion turns was fabricated on a 20 × 20-mm(2) microchip using multistep ultraviolet photolithography and deep reactive ion etching. The BCAAs were fluorescently labeled with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F), followed by reversed-phase separation on the pillar array column.

View Article and Find Full Text PDF

Fluoride concentrations were determined in PM10 samples collected in the urbanized coastal area of the Baltic Sea (Gdynia) in the period between 1 August 2008 and 8 January 2010. F(-) concentrations remained within the range of 0.4-36.

View Article and Find Full Text PDF