Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The aim of the study was to evaluate whether the "Quantitative Blush Evaluator" (QuBE) score is associated with measures of myocardial reperfusion in patients with ST-segment elevation myocardial infarction (STEMI) treated in two hospitals with 24/7 coronary intervention facilities.
Background: QuBE is an open source computer program to quantify myocardial perfusion. Although QuBE has shown to be practical and feasible in the patients enrolled in the Thrombus Aspiration during Percutaneous Coronary Intervention in Acute Myocardial Infarction Study (TAPAS), QuBE has not yet been verified on reperfusion outcomes of primary percutaneous coronary intervention (PCI) patients treated in other catheterization laboratories.
Methods: Core lab adjudicated angiographic outcomes and QuBE values were assessed on angiograms of patients who were enrolled in the PRoximal Embolic Protection in Acute myocardial infarction and Resolution of ST-Elevation (PREPARE) trial. ST-segment resolution immediately after PCI measured by continuous ST Holter monitoring was calculated by a blinded core lab.
Results: The QuBE score could be assessed on 229 of the 284 angiograms (81%) and was significantly associated with visually assessed myocardial blush grade (P < 0.0001). Patients with improved postprocedural Thrombolysis in Myocardial Infarction-graded flow, myocardial blush grade, ST-segment resolution immediately after PCI, or a small infarct size measured by peak CK-MB had a significant better QuBE score.
Conclusions: QuBE is feasible and applicable at angiograms of patients with STEMI recorded at other catheterization laboratories and is associated with measures of myocardial reperfusion.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ccd.22329 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!