Study Design: An in vitro biomechanical cadaver study.

Objectives: To compare the subsidence displacement after cyclic loading among 4 sacral pedicle screw fixations of bicortical, tricortical, standard polymethylmethacrylate (PMMA) augmentation, and sub-endplate PMMA augmentation in osteoporotic condition.

Summary Of Background Data: Implant failure caused by screw loosening is a clinical problem for lumbosacral fusions, especially in osteoporotic patients. To improve sacral screw anchoring strength, the main fixation techniques need to be evaluated biomechanically.

Methods: For this study, 11 fresh osteoporotic cadaver sacra were harvested and bone mineral density was measured with dual-energy radiograph absorptiometry. A 7 mm diameter monoaxial pedicle screw (S1) was randomly assigned by side (left vs. right) and placed bicortically or tricortically. The 2 screws, followed 2000 cyclic compression loading of 30 to 250 N, were removed. The screw tracts were filled up with PMMA, then, screws 5 mm shorter than the bicortical or tricortical fixation were reinserted (defined as standard and sub-endplate PMMA augmented sacral screw fixations, respectively). The PMMA augmented screws were then retested as before. Screw subsidence displacement after 2000 cyclic loading was measured and compared.

Results: The average bone mineral density of 11 specimens was 0.71 g/cm, ranged from 0.65 to 0.78 g/cm. No significant difference of subsidence displacement was detected between tricortical and standard PMMA augmented screws (P>0.05), however, the 2 fixations exhibited markedly less subsidence than bicortical screw (P<0.05). Sub-endplate PMMA augmented screw showed the least subsidence among all the screws (P<0.05).

Conclusions: PMMA augmentation can increase the bonding strength of sacral screw-bone interface and the sub-endplate PMMA augmented sacral screw could obtain the highest stability among the 4 fixation techniques in osteoporotic condition.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BSD.0b013e3181b63f4dDOI Listing

Publication Analysis

Top Keywords

pedicle screw
12
subsidence displacement
12
pmma augmented
12
screw
9
fixation techniques
8
sacral pedicle
8
cyclic loading
8
screw fixations
8
bicortical tricortical
8
tricortical standard
8

Similar Publications

Objective: This study aims to evaluate the clinical outcomes of utilizing C1 posterior arch screws (PAS) combined with C2 translaminar screws as an adjunct for reinforcing upper cervical spine fixation.

Methods: A retrospective analysis was conducted on four male patients who underwent surgery involving C1 PASs and C2 translaminar screws between January 2022 and February 2024. Surgical technique involved the insertion of standard C1 lateral mass screws (LMS) and C2 pedicle screws, followed by the placement of C1 PASs and C2 translaminar screws for additional fixation.

View Article and Find Full Text PDF

A rare pediatric case of thoracic spine giant cell tumor: Clinical implications and surgical strategies.

Int J Surg Case Rep

January 2025

Department of Neurosurgery, Damascus Hospital, Damascus, Syria; Faculty Of Medicine, Al-fourat university, Deir ez-Zor, Syria.

Introduction And Clinical Importance: Giant cell tumor (GCT) is a rare benign bone tumor that usually affects skeletally adult people. While it usually appears in the epiphyseal parts of long bones, it is very rare in the spine, particularly the thoracic spine, especially in pediatric patients.

Case Presentation: An 11-year-old female presented with progressive lower extremity weakness, accompanied by localized back pain and urinary urgency, diagnosed with GCT in the thoracic spine.

View Article and Find Full Text PDF

Purpose: Although idiopathic scoliosis is a common three-dimensional deformity, there is a lack of studies evaluating the associations between the aortic-vertebral distance (AVD) and spinal deformities in all planes. The study therefore aimed to evaluate how the coronal and sagittal curvature, vertebral rotation and aortic-vertebral angle (AVA) affect the AVD in idiopathic scoliosis.

Methods: The AVD, AVA, vertebral rotation and curve angles were measured on preoperative magnetic resonance imaging and radiographs in 46 patients who underwent posterior spinal fusion with pedicle screw instrumentation for idiopathic scoliosis Lenke types 1 and 2.

View Article and Find Full Text PDF

Background: High-grade Isthmic Spondylolisthesis often requires surgical intervention for spinal realignment and decompression. This study describes a modified Bohlman procedure utilizing robotic-assisted navigation and a Globus SI-LOK interbody device.

Methods: A retrospective review was conducted on three patients who underwent the modified Bohlman procedure for high-grade spondylolisthesis at a single hospital between 2022 and 2023.

View Article and Find Full Text PDF

Study Design: Narrative Review.

Objective: The management of spinal tumors requires a multi-disciplinary approach including surgery, radiation, and systemic therapy. Surgical approaches typically require posterior segmental instrumentation to maintain long-term spinal stability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!