Benefits of localization and speech perception with multiple noise sources in listeners with a short-electrode cochlear implant.

J Am Acad Audiol

Department of Otolaryngology-Head and Neck Surgery, University of Iowa, Iowa City, IA 52242-1078, USA.

Published: January 2010

AI Article Synopsis

Article Abstract

Background: Research suggests that for individuals with significant low-frequency hearing, implantation of a short-electrode cochlear implant may provide benefits of improved speech perception abilities. Because this strategy combines acoustic and electrical hearing within the same ear while at the same time preserving low-frequency residual acoustic hearing in both ears, localization abilities may also be improved. However, very little research has focused on the localization and spatial hearing abilities of users with a short-electrode cochlear implant.

Purpose: The purpose of this study was to evaluate localization abilities for listeners with a short-electrode cochlear implant who continue to wear hearing aids in both ears. A secondary purpose was to document speech perception abilities using a speech-in-noise test with spatially separate noise sources.

Research Design: Eleven subjects that utilized a short-electrode cochlear implant and bilateral hearing aids were tested on localization and speech perception with multiple noise locations using an eight-loudspeaker array. Performance was assessed across four listening conditions using various combinations of cochlear implant and/or hearing aid use.

Results: Results for localization showed no significant difference between using bilateral hearing aids and bilateral hearing aids plus the cochlear implant. However, there was a significant difference between the bilateral hearing aid condition and the implant plus use of a contralateral hearing aid for all 11 subjects. Results for speech perception showed a significant benefit when using bilateral hearing aids plus the cochlear implant over use of the implant plus only one hearing aid.

Conclusion: Combined use of both hearing aids and the cochlear implant show significant benefits for both localization and speech perception in noise for users with a short-electrode cochlear implant. These results emphasize the importance of low-frequency information in two ears for the purpose of localization and speech perception in noise.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2809934PMC
http://dx.doi.org/10.3766/jaaa.21.1.6DOI Listing

Publication Analysis

Top Keywords

cochlear implant
36
speech perception
28
short-electrode cochlear
24
hearing aids
24
bilateral hearing
20
localization speech
16
hearing
14
hearing aid
12
aids cochlear
12
implant
11

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?