Field trial of five repellent formulations against mosquitoes in Ahero, Kenya.

US Army Med Dep J

Entomology Department, US Army Medical Research Unit, Kenya.

Published: February 2010

Twelve volunteers, using one leg for repellent application and the other leg as a control, field-tested 5 insect repellent formulations--Avon's (New York, NY) SS220 Spray, SS220 Lotion, and Bayrepel Lotion, and SC Johnson's (Racine, Wisconsin) Autan Bayrepel Lotion--against the standard N,N-diethyl-3-methyl-benzamide (deet) in a rice-growing district near Kisumu, western Kenya, in 2 trials in May and June 2004. In addition to a control leg for each volunteer, an additional control was introduced into the study by the use of a sixth repellent, a "null repellent," which was literally a treatment application of no repellent at all. The 5 active repellent formulations were uniformly applied at the maximum Environmental Protection Agency recommended dose of 1.5 g per 600 cm2 in the first trial and half that dose in the second trial, and none of them failed during the nightly 12-hour test period over 6 consecutive days, May 19 through May 24, 2004, and June 14 through June 19, 2004. However, the repellent control legs demonstrated a statistically significant increased landing rate compared to both the null repellent and the null repellent control leg. This suggests that, in this approach, active repellents increased the capture rate on an adjacent control leg compared to null controls. A single human volunteer can act as his/her own control provided null treatment controls are included.

Download full-text PDF

Source

Publication Analysis

Top Keywords

control leg
12
repellent
9
repellent formulations
8
june 2004
8
repellent control
8
compared null
8
null repellent
8
control
7
leg
5
field trial
4

Similar Publications

Background: Debridement is considered the first step in treatment of chronic wounds, however, current enzymatic and autolytic debridement agents are slow or ineffective. Previous studies have shown positive initial results with EscharEx® (EX-02 formulation), a Bromelain-based enzymatic debridement agent in development for chronic wounds. The main objective of this study was to assess its efficacy in debriding venous leg ulcers (VLU), compared to gel vehicle (GV) as a placebo control and to non-surgical standard of care (NSSOC).

View Article and Find Full Text PDF

Cardiac return assist blanket (CRAB) safely increases central venous pressure.

J Int Med Res

January 2025

Institute for Health Research, the University of Notre Dame Australia, Department of Research, Sir Charles Gairdner Hospital, Nedlands, Australia.

Objective: The cardiac return assist blanket (CRAB) has been designed to increase central venous pressure (CVP) to manage severe hypotension associated with anaphylaxis. This interventional study aimed to identify the relationship between CRAB pressure and CVP. CRAB pressure was also compared with the change in CVP associated with a straight leg raise (SLR), the Trendelenburg position, and 1 L of compound sodium lactate.

View Article and Find Full Text PDF

The purpose of this systematic review and meta-analysis is to evaluate the safety and efficacy of anti-inflammatory-impregnated gelatin sponges in spine surgeries. Gelatin sponges are increasingly used as delivery vehicles for anti-inflammatory and analgesic drugs during spine surgeries. However, concerns about their safety and efficacy persist.

View Article and Find Full Text PDF

TiMON: a real-time integrated monitor for improving the placement and wear of emergency tourniquets.

BMC Emerg Med

January 2025

Wellman Center for Photomedicine, Harvard Medical School, Massachusetts General Hospital, CNY149, 13th St, Charlestown, 02129, MA, USA.

Background: The use of emergency tourniquets among military personnel has helped to dramatically reduce battlefield deaths and has recently gained popularity in the civilian sector. Yet, even well-trained individuals can find it difficult to assess proper tourniquet application. Emergency tourniquets are typically deemed sufficiently tightened through cursory visual confirmation or pulse assessment.

View Article and Find Full Text PDF

Space payloads in orbit are vulnerable to small vibrations from satellite platforms, which can degrade their performance. Traditional methods typically involve installing a passive vibration isolation system between the platform and the payload. However, such systems are usually effective only for high-frequency, large-amplitude vibrations and perform poorly in isolating low-frequency vibrations and resonances below 10 Hz.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!