Objectives: To assess the accuracy and reliability of four-dimensional (4D) ultrasound imaging using spatiotemporal image correlation (STIC) employing three different techniques to measure volumes in vitro.
Methods: Customized miniature balloons attached to a pump system were used to mimic fetal cardiac chambers. After the balloon model had been immersed in a bath filled with viscous gel, 4D datasets were acquired and three methods were used for volume analysis: three dimensional (3D) slice method, Virtual Organ Computer-aided AnaLysis (VOCAL) and VOCAL combined with inversion mode. Accuracy and measurement error were measured as the difference between the volume measurements and the actual volumes. Intraobserver reliability was assessed by computing coefficients of variation (CV) and intraclass correlation (ICC).
Results: Measurement of 76 different volumes, ranging from 0.30 to 4.95 mL, resulted in a total of 912 measurements. The 3D slice method had a mean error of -3.3%, the inversion method underestimated the volumes with a mean error of -6.1%, and VOCAL had a mean error of -2.9%. The 3D slice method had the best agreement (95% limits of agreement (LOA), -11.2 to 4.7%), followed by VOCAL (95% LOA, -14.1 to 8.3%); the inversion mode demonstrated the worst agreement (95% LOA, -21.4 to 9.2%). All three methods were reliable with CV < 10% and ICC > 0.95.
Conclusions: 4D ultrasonography with STIC is a feasible and accurate method for calculating volumes of 0.30 mL upwards. In an in-vitro model the 3D slice method proved accurate, was the least time consuming, had the best reliability and had the smallest LOA. This method may prove useful when applied to in-vivo investigations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/uog.7561 | DOI Listing |
J Cachexia Sarcopenia Muscle
January 2025
Department of Medical Oncology, Lille University Hospital, Lille, France.
Background: Advanced pancreatic ductal adenocarcinoma (aPDAC) is often accompanied by significant muscle mass loss, contributing to poor prognosis. SarcAPACaP, an ancillary study of the GERCOR-APACaP phase III trial, evaluated the role of adapted physical activity (APA) in aPDAC Western patients receiving first-line chemotherapy. The study aimed to assess (1) the potential impact of computed tomography (CT)-quantified muscle mass before and during treatments on health-related quality of life (HRQoL) and overall survival (OS) and (2) the role of APA in mitigating muscle mass loss.
View Article and Find Full Text PDFMagn Reson Med
January 2025
Department of Radiology, University of Missouri, Columbia, Missouri, USA.
Purpose: The aim of the work is to develop a cascaded diffusion-based super-resolution model for low-resolution (LR) MR tagging acquisitions, which is integrated with parallel imaging to achieve highly accelerated MR tagging while enhancing the tag grid quality of low-resolution images.
Methods: We introduced TagGen, a diffusion-based conditional generative model that uses low-resolution MR tagging images as guidance to generate corresponding high-resolution tagging images. The model was developed on 50 patients with long-axis-view, high-resolution tagging acquisitions.
Magn Reson Med
January 2025
Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China.
Purpose: This work aims to raise a novel design for navigator-free multiband (MB) multishot uniform-density spiral (UDS) acquisition and reconstruction, and to demonstrate its utility for high-efficiency, high-resolution diffusion imaging.
Theory And Methods: Our design focuses on the acquisition and reconstruction of navigator-free MB multishot UDS diffusion imaging. For acquisition, radiofrequency-pulse encoding was used to achieve controlled aliasing in parallel imaging in MB imaging.
Sci Rep
January 2025
Department of Neurosurgery, University Hospital Tübingen, Tübingen, Germany.
To compare 1D (linear) tumor volume calculations and classification systems with 3D-segmented volumetric analysis (SVA), focusing specifically on their effectiveness in the evaluation and management of NF2-associated vestibular schwannomas (VS). VS were clinically followed every 6 months with cranial, thin-sliced (< 3 mm) MRI. We retrospectively reviewed and used T1-weighted post-contrast enhanced (gadolinium) images for both SVA and linear measurements.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Anatomy, Nihon University School of Dentistry, Tokyo, Japan.
This study presents a novel method for creating customized brain slice matrices using Computer-Aided Design (CAD) and 3D printing technology. Brain Slice Matrices are essential jigs for the reproducible preparation of brain tissue sections in neuroscience research. Our approach leverages the advantages of 3D printing, including design flexibility, cost-effectiveness, and rapid prototyping, to produce custom-made brain matrices based on specific morphometric measurements.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!