Conclusion: The external neck brace (ENB) is a new concept in the improvement of peristomal fixation of an automatic stoma valve (ASV), which was evaluated with a new imaging method. The addition of the ENB to the Flexiderm (FLD) and Xtrabase (XB) adhesives significantly reduced absolute mean differences between the speech and the non-speech conditions.

Objectives: After total laryngectomy, peristomal fixation problems of adhesives and stoma valves are still the main reasons for the relatively small number of patients that actually use an ASV on a daily basis. Several concepts could not prevent these fixation problems. To overcome or at least diminish these attachment problems, an ENB has been developed to support peristomal adhesives. The mechanism behind this brace is that it absorbs the high stomal pressures created during tracheoesophageal speech. In this pilot study the mechanism outlined above was objectified using 3D stereophotogrammetrical measurements.

Methods: This was a prospective clinical pilot study in a university hospital setting, involving nine laryngectomized patients. Ten 3D images were taken of all patients using stereophotogrammetry; five pictures during a moment of speech and five during a non-speech condition. Two different peristomal adhesives were used during these two conditions: the Provox Flexiderm (FLD) adhesive and the Provox Xtrabase (XB) adhesive, both with and without the addition of the ENB. Besides these four combinations, a final fifth set-up using all the components (FLD + XB-ring + ENB) was added. Absolute mean differences were compared between two photographs of the area of interest, which is covered by the adhesive for all five different set-ups mentioned above. This was done during speech and non-speech conditions.

Results: Absolute mean differences at the region of the base plate between speech and non-speech conditions were most obvious while using just the FLD adhesive (4.70 mm). The use of the ENB significantly reduced the absolute mean difference to 0.58 mm (p < 0.02). The suggested set-up with a basis of the FLD adhesive combined with the solid ring extracted from the XB adhesive and the ENB showed the smallest absolute mean difference of 0.38 mm between speech and non-speech conditions (p < 0.025).

Download full-text PDF

Source
http://dx.doi.org/10.3109/00016480903426600DOI Listing

Publication Analysis

Top Keywords

speech non-speech
20
peristomal fixation
12
absolute differences
12
fld adhesive
12
external neck
8
neck brace
8
support peristomal
8
fixation automatic
8
automatic stoma
8
stoma valve
8

Similar Publications

Short-term memory for sequences of verbal items such as written words is reliably impaired by task-irrelevant background sounds, a phenomenon known as the "Irrelevant Sound Effect" (ISE). Different theoretical accounts have been proposed to explain the mechanisms underlying the ISE. Some of these assume specific interference between obligatory sound processing and phonological or serial order representations generated during task performance, whereas other posit that background sounds involuntarily divert attention away from the focal task.

View Article and Find Full Text PDF

Rhythm perception in speech and non-speech acoustic stimuli has been shown to be affected by general acoustic biases as well as by phonological properties of the native language of the listener. The present paper extends the cross-linguistic approach in this field by testing the application of the iambic-trochaic law as an assumed general acoustic bias on rhythmic grouping of non-speech stimuli by speakers of three languages: Arabic, Hebrew and German. These languages were chosen due to relevant differences in their phonological properties on the lexical level alongside similarities on the phrasal level.

View Article and Find Full Text PDF

Unlabelled: Central auditory disorders (CSD) - this is a violation of the processing of sound stimuli, including speech, above the cochlear nuclei of the brain stem, which is mainly manifested by difficulties in speech recognition, especially in noisy environments. Children with this pathology are more likely to have behavioral problems, impaired auditory, linguistic and cognitive development, and especially difficulties with learning at school.

Objective: To analyze the literature data on the epidemiology of central auditory disorders in school-age children.

View Article and Find Full Text PDF

Objective: Clinicians face challenges in managing the growing population of patients with limited English proficiency (LEP) and hearing loss (HL) in the United States. This study seeks to investigate provider perspectives on evaluating, counseling, and treating HL in LEP patients.

Study Design: Prospective descriptive study.

View Article and Find Full Text PDF

The ability to process auditory information is one of the foundations of the ability to appropriately acquire language. Moreover, early difficulties in basic auditory abilities have cascading effects on the appropriate wiring of brain networks underlying higher-order linguistic processes. Language impairments represent core difficulties in two different but partially overlapping disorders: developmental language disorder (DLD) and autism spectrum disorder (ASD).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!