A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Three-dimensional analysis of pulmonary nodules: variability of semiautomated volume measurements between different versions of the same software. | LitMetric

Purpose: This study was done to evaluate the variability of semiautomated volume measurements of solid pulmonary nodules between two different versions of the same volumetric software.

Materials And Methods: The volumes of 100 solid intraparenchymal nodules (mean volume 88.10 mm(3); range 7.36-595.25 mm(3)) studied with the same multidetector computed tomography (MDCT) protocol were determined using two different versions of the same volumetric software (LungCARE 2006G and LungCARE 2007S). The 2006G version is based on a single-segmentation algorithm, whereas the newer version features two algorithms: SmallSizeNodule and AllSizeNodule. The results obtained with the 2006G version were compared with those of the 2007S version with the SmallSizeNodule algorithm, as recommended by the user manual. In addition, we compared the volumetric measurements obtained by the two different algorithms of the 2007S version.

Results: The 2006G version and the 2007S version with the SmallSizeNodule algorithm agreed in only two of 100 cases and showed a mean variability of 1.66% (range 0%-8.78%). A more significant volumetric discrepancy was observed between the two different algorithms of the 2007S version, with the AllSizeNodule algorithm providing on average larger volumes (mean variability 71.08%; range 6.02%-218.80%) than SmallSizeNodule. Volume discrepancies were more pronounced in the subgroups of smaller nodules in all comparisons.

Conclusions: There is variability also in the results provided by different versions of the same volumetric software, and this may affect the calculation of the nodule-doubling time. Computer-aided assessment of the growth of lung nodules should always be performed using the same version of volumetric software and the same segmentation algorithm.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11547-010-0511-6DOI Listing

Publication Analysis

Top Keywords

versions volumetric
12
volumetric software
12
2006g version
12
2007s version
12
pulmonary nodules
8
variability semiautomated
8
semiautomated volume
8
volume measurements
8
version
8
version smallsizenodule
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!