Standardisation of 124SB and 152EU using software coincidence counting system.

Appl Radiat Isot

Czech Metrology Institute, Inspectorate for Ionizing Radiation, Prague, Czech Republic.

Published: August 2010

Activities of the radionuclides (124)Sb and (152)Eu were determined by the efficiency extrapolation method applied to 4pi(PC)-gamma coincidence counting. The (124)Sb sources were prepared from a solution with the chemical form of 50 microg g(-1) SbCl(3) in 2 M HCl. To inhibit the volatility of antimony chlorides, the sources were slowly dried in a H(2)S atmosphere with relative humidity of 76% for about 48 h. This procedure increased the beta detection efficiency up to 0.98, which simplified the standardisation. In the (152)Eu standardisation, the optimal gamma-ray energy window setting to achieve a linear dependency and the correct slope of the extrapolation curve were derived by means of software coincidence counting system using offline evaluation of data with different coincidence parameter settings. The results obtained by the software coincidence counting system were compared with those obtained by the conventional coincidence method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2009.12.029DOI Listing

Publication Analysis

Top Keywords

coincidence counting
16
software coincidence
12
counting system
12
124sb 152eu
8
coincidence
6
standardisation 124sb
4
152eu software
4
counting
4
system activities
4
activities radionuclides
4

Similar Publications

Quantum walks on photonic platforms represent a physics-rich framework for quantum measurements, simulations and universal computing. Dynamic reconfigurability of photonic circuitry is key to controlling the walk and retrieving its full operation potential. Universal quantum processing schemes based on time-bin encoding in gated fibre loops have been proposed but not demonstrated yet, mainly due to gate inefficiencies.

View Article and Find Full Text PDF

The massic activity of Ac in 0.1 mol/L HCl was measured by multiple primary methods over four consistent measurement campaigns. Results from the triple-to-double coincidence ratio (TDCR) method of liquid scintillation (LS) counting were in accord with other LS-based primary methods.

View Article and Find Full Text PDF

Background: Assessing the performance of spectral detectors is an important but nontrivial problem. In the past few years, detective quantum efficiency-(DQE)-like quantities have been proposed that allow quantifying the spatial-spectral performance for certain tasks. In previous publications, we have presented and validated an approach to determine detector properties like the modulation transfer function (MTF), the noise power spectrum (NPS), and the DQE based on an end-to-end Monte Carlo model of the detection process.

View Article and Find Full Text PDF

Usefulness of a new anthropomorphic phantom simulating the chest and abdomen regions in PET tests.

Ann Nucl Med

December 2024

Division of Functional Imaging, Exploratory Oncology Research and Clinical Trial Center, National Cancer Center, 6-5-1 Kashiwanoha, Kashiwa, 277-8577, Japan.

Objective: To investigate the clinical utility of a new anthropomorphic phantom that reproduces the chest and abdomen better than the conventional National Electrical Manufacturers Association (NEMA) body phantom, count rates and image quality of PET images obtained from patients were evaluated.

Methods: Anthropomorphic phantoms were used to include radioactivity in the lung, liver, kidney, and background regions. Two NEMA body phantoms were used for chest and abdominal assessments.

View Article and Find Full Text PDF

Introduction: Critical coronavirus disease (COVID-19) patients have a high mortality rate. To identify high-risk patients, first-level healthcare facilities can use the neutrophil-lymphocyte ratio (NLR) and the plateletlymphocyte ratio (PLR) as prognostic markers. We aimed to assess the NLR and the PLR profile in critically ill COVID-19 patients to predict disease severity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!