To evaluate the accuracy of the UEBE Visomat Comfort form device for home blood pressure measurement tested following the recommendations of the International Protocol of the European Society of Hypertension. Device evaluation was performed in 33 participants with a mean +/- standard deviation age of 56.5+/-18.3 years (range 30-91 years). Their systolic blood pressure (SBP) was 143.6+/-25.3 mmHg (range 94-180 mmHg), diastolic blood pressure (DBP) was 88.8+/-15.4 mmHg (range 64-116 mmHg), and upper arm circumference was 30.2+/-3.2 cm (range 24.5-39.0 cm). BP measurements were performed in the sitting position. The Visomat Comfort form passed all three phases of the European Society of Hypertension protocol for SBP and DBP. Mean BP differences for the Visomat Comfort form (device-observer) were -2.5+/-5.9 mmHg for SBP and -2.4+/-5.4 mmHg for DBP. Similar device-observer differences were observed in the participants divided into two subgroups according to whether their arm circumference was above or below the median in the group. In conclusion, these results indicate that the UEBE Visomat Comfort form monitor can be recommended for clinical use in the adult population over a wide range of arm circumferences.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MBP.0b013e32833531deDOI Listing

Publication Analysis

Top Keywords

visomat comfort
20
comfort form
20
blood pressure
16
form device
8
device blood
8
pressure measurement
8
international protocol
8
uebe visomat
8
european society
8
society hypertension
8

Similar Publications

Objective: To validate the UEBE Visomat Double Comfort, an upper arm blood pressure monitor designed for self-measurement of blood pressure and for clinical use in a general population according to the European Society of Hypertension International Protocol revision 2010.

Methods: The device is provided with two operational modalities, a microphonic mode and an oscillometric mode. In this study, the oscillometric modality was tested.

View Article and Find Full Text PDF

To evaluate the accuracy of the UEBE Visomat Comfort form device for home blood pressure measurement tested following the recommendations of the International Protocol of the European Society of Hypertension. Device evaluation was performed in 33 participants with a mean +/- standard deviation age of 56.5+/-18.

View Article and Find Full Text PDF

The objective of this study was to determine the accuracy of the UEBE visomat comfort eco blood pressure measuring device tested according to the requirements of the International Protocol of the European Society of Hypertension. The device evaluation was performed in 33 participants with a mean+/-SD age of 54.3+/-18.

View Article and Find Full Text PDF

An appropriate cuff according to the individual's arm circumference is recommended with all blood pressure (BP) monitors. An electronic device for home monitoring has been developed (Visomat Comfort 20/40) that estimates the individual's arm circumference by measuring the cuff filing volume and makes an adjustment of measured BP taking into account the estimated arm circumference. Thus the manufacturer recommends the use of a single cuff for arm circumference 23-43 cm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!